Community Profile

photo

Pat Gipper


Array of Engineers

Last seen: ein Tag vor Aktiv seit 2020

Statistiken

All
  • Personal Best Downloads Level 4
  • 5-Star Galaxy Level 1
  • 6 Month Streak
  • Knowledgeable Level 3
  • Revival Level 1
  • Explorer
  • First Submission
  • Knowledgeable Level 2
  • First Answer

Abzeichen anzeigen

Content Feed

Anzeigen nach

Gesendet


Frequency Response Analyzer
Perform frequency analysis of your Simulink model without linearization

3 Monate vor | 372 Downloads |

Thumbnail

Beantwortet
PV MPPT Tracking Failing PV Array Current or Volatge Goes negative
Hi Ishaan. I found that a perturbation of 1% (Constant2 with value of 1) was too large in the controller. If you reduce the Cons...

fast 2 Jahre vor | 0

| akzeptiert

Beantwortet
Model error in Simulink
It is having problems simulating an ideal op amp with infinite gain. If you intend on configuring the LM386 op amp as an invert...

fast 2 Jahre vor | 0

Beantwortet
create a variable that changes its value(polynomial equation) for different time periods
Maybe something like this.

fast 2 Jahre vor | 1

Beantwortet
Adding noise to a PID signal
Hi Nathan, You can use the lsim command to get a general response of your controller. I think you want to see the response when...

fast 2 Jahre vor | 0

Frage


Why the different response of two Simulink models?
Here is a follow-on question to this original question: How can I remove the few peaks before the overshoot, so I only have the...

etwa 2 Jahre vor | 1 Antwort | 0

1

Antwort

Beantwortet
How can I remove the few peaks before the overshoot, so I only have the overshoot peak and then it directly transition into steady state?
Hi Samuel. I found tuning the derivative to be difficult too. Eventually I settled in on P=3.5, I=850, D=0.01 and N=850. The def...

etwa 2 Jahre vor | 0

| akzeptiert

Beantwortet
Can you let me know how to solve my errors? there are 4 errors in my simulink.
You had two issues. One was the integrators in Current_Controller were implimented using the Memory in the feedback path causing...

etwa 2 Jahre vor | 1

| akzeptiert

Beantwortet
Data type mismatch error in Simulink
I saw a number of other issues in this model. 1) I think the inverter needs a ground reference added on the emitters of the low...

etwa 2 Jahre vor | 0

| akzeptiert

Beantwortet
I need more explanations for the described hydraulic simulation
The pump in this model acts in a fixed displacement mode that produces a given flow rate regardless of its output pressure. When...

mehr als 2 Jahre vor | 0

Beantwortet
Filter background from audio file
Check out this previous answer. A different type of owl, but the same concept. Using Spectrogram to Design a Filter - (mathwork...

mehr als 2 Jahre vor | 0

Beantwortet
Simulation of the step response of a time delay system with a PID controller is contorted.
Those sharp transients in the closed loop response are the echoes of the step input as filtered by the transfer function that ar...

mehr als 2 Jahre vor | 0

Beantwortet
3rd Order ODE on Simulink
I approximated the required doublet input into an update to my comment with a summation of two very short pulse generators.

mehr als 2 Jahre vor | 0

Beantwortet
Why is my step response going down instead of up?
I would focus on your equation for zeta on line 60. It is resulting in a negative value (negative damping=bad!) which gives unst...

mehr als 2 Jahre vor | 1

| akzeptiert

Beantwortet
An electric circuit that includes a voltage source E with an internal resistance r, and a load resistance R is shown in the figure.
Probably late for your homework assignment. Can you write the equation for the power dissipated in R leaving R as a variable? Do...

mehr als 2 Jahre vor | 0

Beantwortet
Unexpected noise in output voltage for buck converter
The Puse Generator has a period of 1/100000 seconds, which is injecting 100 KHz pulses into your system. The ripple is simply th...

mehr als 2 Jahre vor | 0

Beantwortet
Reproduce electric motor maps as images in Matlab Simulink
A similar question was answered suggesting importing the image into Matlab and then using ginput to extract coordinates of the a...

fast 3 Jahre vor | 0

Beantwortet
Determining time elapsed in between two successive pulses of a signal
I updated your code a bit and fed in an artificial signal. It works but has a slight error due to loop delays running on my comp...

etwa 3 Jahre vor | 1

| akzeptiert

Beantwortet
How best to gather signals from all over a SIMULINK model to one subsystem
I moved your root model into a subsystem and used Bus Element Out(s), which was then connected to a new input on "get data" subs...

etwa 3 Jahre vor | 0

Beantwortet
A question about FOC current control for PMSM
The decoupling control is not quite correct for the PMSM motor you are using. You need to insert a multiplier by the number of p...

etwa 3 Jahre vor | 1

| akzeptiert

Beantwortet
How to measure the steady state amplitude of a control system output
Try using this app. It injects a sine wave and measures the gain and phase after a number of cycles that you specify. https://w...

etwa 3 Jahre vor | 0

Beantwortet
How to programmatically know if a block is a sink block?
I had to add some complexity to your code to make it work on my sample file. modelfile = 'SinkXY';% Or whatever your model file...

etwa 3 Jahre vor | 0

Beantwortet
Need help with simple Simulink
This seems to do the trick. It produces the following result.

etwa 3 Jahre vor | 1

| akzeptiert

Beantwortet
Simulation of a missile valve with Simscape
Hi Tom, A flip-flop will latch the valve shut once the flow reaches the threshold and keep it shut until you manually reset it....

etwa 3 Jahre vor | 1

| akzeptiert

Beantwortet
Coding philosophy : Is using global goto like using a global variable?
The thing about global visibility is that this signal can be accessible anywhere in the entire model, from sub-system to sub-sys...

etwa 3 Jahre vor | 1

Beantwortet
Calling a function using ode45 in App Designer results in unrecognized function
Note that I had answered my own question.

etwa 3 Jahre vor | 0

Beantwortet
How make single block diagram with this given parameters?
Hi. If you are using a Transfer Fcn block and have the coefficients defined in your workspace, then enter the equations in the b...

etwa 3 Jahre vor | 1

| akzeptiert

Beantwortet
Frequency domain to Time domain Using IFFT : Symmetric figure problem
Your function produced a vector of complex numbers called "A". The original sequence will be reproduced using ifft(A). But the f...

etwa 3 Jahre vor | 0

Beantwortet
Substitute s for jw in a transfer function
Matlab uses the reserved constant "i" which is set equal to sqrt(-1). Using your transfer function as defined try the following...

etwa 3 Jahre vor | 0

Mehr laden