Hello,
I would like to realize a missile valve in Simscape. For the valve I use the Local Restriction. Now I would like to close the valve when a previously defined mass or volume flow is reached and keep it closed until the end of the simulation.
A first approach was to implement an if-condition in Simulink. I was able to use this to close the valve when a defined mass flow was reached but not able to keep it closed, as it reopens as the mass flow drops.
Does anyone have an idea how I can keep the valve closed state? Is there a corresponding block in Simulink or Simscape?
Thanks a lot and greetings
Tom
0 Kommentare
Akzeptierte Antwort
Pat Gipper
am 11 Feb. 2021
Hi Tom,
A flip-flop will latch the valve shut once the flow reaches the threshold and keep it shut until you manually reset it. That is an S-R Flip-Flop in the picture.
2 Kommentare
Pat Gipper
am 11 Feb. 2021
Your welcome Tobias. I was worried that what you really wanted was less electronic and more of something that could be directly implemented in the hydraulic world (e.g. hydraulic fuse). But if all you needed was the function then the flip-flop works.