Community Profile

photo

Guy Rouleau

Last seen: Today Aktiv seit 2008

Followers: 0   Following: 0

Kontakt

Statistiken

All
  • Thankful Level 2
  • 36 Month Streak
  • Solver
  • GitHub Submissions Level 3
  • Personal Best Downloads Level 3
  • Editor's Pick
  • First Review
  • 5-Star Galaxy Level 5
  • First Submission
  • Pro
  • Revival Level 2
  • Knowledgeable Level 5

Abzeichen anzeigen

Feeds

Beantwortet
Why do I get the Simulink error: "Cannot create variable 'streamout' in workspace"
"streamout" is from a realtively old version, around R2016. I would recommend upgrading. If not possible, look in your "tempdir...

mehr als 2 Jahre vor | 0

Beantwortet
Export model as FMU for Cosimulation stand-alone
Beginning with R2020a, you can export your Simulink model as a standalone FMU with Simulink Compiler. When a third-party tool ru...

mehr als 3 Jahre vor | 2

Beantwortet
Is there a way to stop compiling process when the model has started to compile in Simulink?
In MATLAB R2020b and before, there is no way to interrupt the model compilation. We are aware that this is a common pain point ...

mehr als 3 Jahre vor | 1

Beantwortet
How to deploy simscape models with tunable block parameters?
It looks like you need to enable the display of Simscape run-tim parameter settings in blocks dialog, this cna be done fomr the ...

mehr als 3 Jahre vor | 0

| akzeptiert

Beantwortet
Creating a standalone .exe of an .m file that calls a simulink model
In R2020a, a new product Simulink Compiler has been released to address this exact use case. See an example here.

etwa 4 Jahre vor | 5

Beantwortet
Matlab Compiler And Simulink
In R2020a, a new product Simulink Compiler has been released to address this exact use case. See an example here.

etwa 4 Jahre vor | 3

Beantwortet
Has anyone solved this issue in 2018b? - Undefined function or variable 'fallbackType'
This is a bug in MATLAB R2018b. To work around, enable the option "allow setting breakpoints during simulation" from the Simulat...

fast 5 Jahre vor | 2

| akzeptiert

Beantwortet
Is there any way to use a block that uses absolute time (e.g., Discrete-Time Integrator) in a referenced model executed by a function-call subsystem?
If you know what sample time at which the Discrete-Time Integrator will be triggered, you can use it in Accumulator mode. This w...

mehr als 7 Jahre vor | 1

Beantwortet
Transform Sensor - Problem with Velocity
One possible explanation is that signals input to S->PS blocks are discrete and filtering is disabled in the S->PS block. Try...

etwa 9 Jahre vor | 0

Beantwortet
generate text in simulink
There are 2 possibilities here: 1 - It is possible to define enumerated types in Simulink. With those, you can define for exa...

etwa 9 Jahre vor | 0

Beantwortet
Simulink block from workspace
I recommend going through the "Importing Signal Data in Simulink" section of the doc: http://www.mathworks.com/help/simulink/...

etwa 9 Jahre vor | 0

Beantwortet
Second Generation Sim Mechanics Motion Actuation
Sicne you don't provide the error, it is difficult to diagnose... The "Joint Actuation" doc page explains what you need to actua...

etwa 9 Jahre vor | 0

Beantwortet
Simulink - Excel
The Signal Builder block allows you to import a signal directly from Excel: http://www.mathworks.com/help/simulink/slref/sign...

mehr als 9 Jahre vor | 1

Beantwortet
Simulink : Slow editing of Data Store Memory with Matlab R2011B - how to make it faster ?
I am not 100% sure this will fix it, but try those bug reports: http://www.mathworks.com/support/bugreports/874385 http://...

fast 10 Jahre vor | 0

Beantwortet
(Simulink) Triggered Delay Line gone in 2014a. Replacements?
Look at the doc doc page for this block: http://www.mathworks.com/help/dsp/ref/triggereddelaylineobsolete.html The first t...

fast 10 Jahre vor | 0

Beantwortet
A ramp block going backwards?
You are probably using a variable step solver. Variable step solvers often need to take steps backward to ensure they respect th...

fast 10 Jahre vor | 0

| akzeptiert

Beantwortet
Using mathematica code in Simulink
Almost... look at this link: http://blogs.mathworks.com/seth/2013/10/10/from-symbolic-to-simulink

etwa 10 Jahre vor | 0

Beantwortet
Is there any limitation in simscape in adding two types of sensors to a circuit?
Torque sensor allows zero motion, it needs to be connected in series. It is like a real physical torque sensor.

etwa 10 Jahre vor | 0

| akzeptiert

Beantwortet
Sources for learning the intricacies of Simulink?
I try my best to describe important Simulink intricacies here: http://blogs.mathworks.com/seth/ Specific to s-function, he...

mehr als 10 Jahre vor | 0

Beantwortet
Terminology 101: XPC , Real-Time, ERT, SIL, PIL, External Mode
I like this page for HIL: http://www.mathworks.com/discovery/real-time-testing.html This section of the doc will help for ...

mehr als 10 Jahre vor | 0

Beantwortet
Is there a possible way to include enumeration in Signal builder function to define inputs?
Not possible... please contact support to explain your use case so it can be considered in future releases. For now, I would ...

mehr als 10 Jahre vor | 0

| akzeptiert

Beantwortet
Slow down Simulink to synchronize it with external session (JADE)
It is not clear how you interface with the external tool, but it looks lik an S-function is the way to go. In an S-Function (...

mehr als 10 Jahre vor | 1

| akzeptiert

Beantwortet
How to get sample time of the model through scrip?
Simulink.BlockDiagram.getSampleTimes http://www.mathworks.com/help/simulink/slref/simulink.blockdiagram.getsampletimes.html

mehr als 10 Jahre vor | 1

Beantwortet
Non-zero start time in Rapid Simulation Target
I will not go into details... with RSim target you have an option to choose a solver. See this link to see how to configure this...

mehr als 10 Jahre vor | 0

Beantwortet
robotic arm force feedback simulation
This is very close to that you need: http://www.mathworks.com/help/physmod/sm/examples_v2/computing-actuator-torques-using-in...

mehr als 10 Jahre vor | 0

| akzeptiert

Beantwortet
Simulink Block execution information problem
Display the sorted order: http://www.mathworks.com/help/simulink/ug/controlling-and-displaying-the-sorted-order.html Here ...

mehr als 10 Jahre vor | 0

| akzeptiert

Beantwortet
linmod or linearize?
Here it is: http://www.mathworks.com/help/slcontrol/ug/linearizing-nonlinear-models.html#bsp453g-1 In short, the answer is...

mehr als 10 Jahre vor | 0

Beantwortet
Problem in linearizing a Simulink model
It is difficult to say without looking inside the subsystem in your model. A few tips: - If you have Simulink Control Design...

mehr als 10 Jahre vor | 0

| akzeptiert

Beantwortet
How do you convert a virtual subsystem to a subsystem which can be converted to referenced model?
The subsystem need to be atomic. Right-click on it, parameters, you should see a "Treat as atomic unit" checkbox. http://w...

mehr als 10 Jahre vor | 2

| akzeptiert

Beantwortet
Can I use embedded matlab functions in simulink models? Is it a good practice to use this?
yes, and yes! (but like all good things... don't abuse it)

mehr als 10 Jahre vor | 0

Mehr laden