The Discrete Transfer Fcn block implements the z-transform transfer function as follows:
where m+1 and n+1 are the number of numerator and denominator coefficients, respectively. num and den contain the coefficients of the numerator and denominator in descending powers of z. num can be a vector or matrix, while den must be a vector. The order of the denominator must be greater than or equal to the order of the numerator.
Specify the coefficients of the numerator and denominator polynomials in descending powers of z. This block lets you use polynomials in z to represent a discrete system, a method that control engineers typically use. Conversely, the Discrete Filter block lets you use polynomials in z-1 (the delay operator) to represent a discrete system, a method that signal processing engineers typically use. The two methods are identical when the numerator and denominator polynomials have the same length.
The Discrete Transfer Fcn block applies the z-transform transfer function to each independent channel of the input. The Input processing parameter allows you to specify whether the block treats each column of the input as an individual channel (frame-based processing) or each element of the input as an individual channel (sample-based processing). To perform frame-based processing, you must have a DSP System Toolbox™ license.
Specifying Initial States
Use the Initial states parameter to specify the initial filter states. The initial states you specify are the initial conditions of the unit delay blocks that are used in the filter digram implementing the discrete transfer function.
To determine the number of initial states you must specify and how to specify them, use the following tables.
Frame-Based Processing
Input | Number of Channels | Valid Initial States (Dialog Box) | Valid Initial States (Input Port) |
---|---|---|---|
| 1 |
|
|
| N |
|
|
Sample-Based Processing
Input | Number of Channels | Valid Initial States (Dialog Box) | Valid Initial States (Input Port) |
---|---|---|---|
| 1 |
|
|
| N |
|
|
| K × N |
|
|
When the Initial states is a scalar, the block initializes all filter
states to the same scalar value. To initialize all states to zero, enter
0
. When the Initial states is a vector
or a matrix, each vector or matrix element specifies a unique initial state for a
corresponding delay element in a corresponding channel:
The vector length must equal the number of delay elements in the filter,
M = max(number of zeros, number of poles)
.The matrix must have the same number of rows as the number of delay elements in the filter,
M = max(number of zeros, number of poles)
. The matrix must also have one column for each channel of the input signal.
The following example shows the relationship between the initial filter output and the initial input and state. Given an initial input u1, the first output y1 is related to the initial state [x1, x2] and initial input by as follows:
Examples
Designing a High Angle of Attack Pitch Mode Control
Use the Control System Toolbox™ and Simulink® Control Design™ to interact with Simulink to design a digital pitch control for the aircraft. In this example, we will design the controller to permit the aircraft to operate at a high angle of attack with minimal pilot workload.
Ports
Input
u — Input signal
scalar | vector | matrix
Input signal, specified as a scalar, vector, or matrix.
When you set the Input
processing parameter to Columns as channels
(frame based)
, the block supports variable-size input
signals, that is, you can change the frame size (number of rows) of the
signal during simulation but the number of channels (columns) must
remain constant. (since R2024a)
Data Types: single
| double
| int8
| int16
| int32
| fixed point
Num — Numerator coefficients
scalar | vector | matrix
Coefficients of the numerator polynomial specified as a vector or matrix in descending powers of z. Use a row vector to specify the coefficients for a single numerator polynomial. Use a matrix to specify coefficients for multiple filters to be applied to the same input. Each matrix row represents a set of filter taps. The order of the denominator must be greater than or equal to the order of the numerator.
Dependencies
To enable this port, set Numerator Source to
Input port
.
Numerator and denominator coefficients must have the same complexity. They can have different word lengths and fraction lengths.
Data Types: single
| double
| int8
| int16
| int32
| fixed point
Den — Denominator coefficients
scalar | vector | matrix
Coefficients of the denominator polynomial specified as a vector in descending powers of
z. Use a row vector to specify the coefficients
for a single denominator polynomial. Use a matrix to specify
coefficients for multiple filters to be applied to the same input. Each
matrix row represents a set of filter taps. The order of the denominator
must be greater than or equal to the order of the numerator. The leading
denominator coefficient cannot be 0
.
Dependencies
To enable this port, set Denominator Source
to Input port
.
Numerator and denominator coefficients must have the same complexity. They can have different word lengths and fraction lengths.
To set Denominator Source to
Input port
, you must select the
Optimize by skipping divide by leading denominator
coefficient (a0) parameter. The block ignores the
leading denominator coefficient value a0 and replaces it with a
1.
Data Types: single
| double
| int8
| int16
| int32
| fixed point
External reset — External reset signal
scalar
External reset signal, specified as a scalar. When the specified trigger event occurs, the block resets the states to their initial conditions.
Tip
The icon for this port changes based on the value of the External reset parameter.
Dependencies
To enable this port, set External reset to
Rising
,
Falling
,
Either
,
Level
, or Level
hold
.
Limitations
The reset signal must be a scalar of type single, double, Boolean, or integer.
Fixed-point data types, except for ufix1
, are not
supported.
Data Types: single
| double
| Boolean
| int8
| int16
| int32
| fixed point
x0 — Initial states
scalar | vector | matrix
Initial states, specified as a scalar, vector, or matrix. For more information about specifying states, see Specifying Initial States. States are complex when either the input or the coefficients are complex.
Dependencies
To enable this port, set Initial states
Source to Input
port
.
Data Types: single
| double
| int8
| int16
| int32
| fixed point
Output
Port_1 — Output signal
scalar | vector | matrix
Output signal specified as a scalar, vector, or matrix.
When you set Sample time to
-1
, sample time of the output signal is same as the
sample time of the input signal u.
Data Types: single
| double
| int8
| int16
| int32
| fixed point
Parameters
Main
Numerator Source — Source of numerator coefficients
Dialog
(default) | Input port
Specify the source of the numerator coefficients as
Dialog
or Input
port
.
Programmatic Use
Block Parameter:
NumeratorSource |
Type: character vector |
Values:
'Dialog' | 'Input port' |
Default:
'Dialog'
|
Numerator Value — Numerator coefficients
[1]
(default) | scalar | vector | matrix
Numerator coefficients of the discrete transfer function. To specify the coefficients,
set the Source to
Dialog
. Then, enter the coefficients in
Value as descending powers of
z. Use a row vector to specify the coefficients
for a single numerator polynomial. Use a matrix to specify coefficients
for multiple filters to be applied to the same input. Each matrix row
represents a set of filter taps.
Dependencies
To enable this parameter, set the Numerator
Source to Dialog
.
Programmatic Use
Block Parameter:
Numerator |
Type: character vector |
Values: scalar | vector | matrix |
Default:
'[1]'
|
Denominator Source — Source of denominator coefficients
Dialog
(default) | Input port
Specify the source of the denominator coefficients as
Dialog
or Input
port
.
To set Denominator Source to Input
port
, you must select the Optimize by
skipping divide by leading denominator coefficient (a0)
parameter.
Programmatic Use
Block Parameter:
DenominatorSource |
Type: character vector |
Values:
'Dialog' | 'Input port' |
Default:
'Dialog'
|
Denominator Value — Denominator coefficients
[1 0.5]
(default) | scalar | vector | matrix
Denominator coefficients of the discrete transfer function. To specify
the coefficients, set the Source to
Dialog
. Then, enter the coefficients in
Value as descending powers of
z. Use a row vector to specify the coefficients
for a single denominator polynomial. Use a matrix to specify
coefficients for multiple filters to be applied to the same input. Each
matrix row represents a set of filter taps.
When you select the Optimize by skipping divide by leading denominator coefficient (a0) parameter, an error occurs if you specify the denominator coefficients in the block dialog box and a0 ≠ 1.
Dependencies
To enable this parameter, set the Denominator
Source to Dialog
.
Programmatic Use
Block Parameter:
Denominator |
Type: character vector |
Values: scalar | vector | matrix |
Default:
'[1 0.5]'
|
Initial states Source — Source of initial states
Dialog
(default) | Input port
Specify the source of the initial states as
Dialog
or Input
port
.
Programmatic Use
Block Parameter:
InitialStatesSource |
Type: character vector |
Values:
'Dialog' | 'Input port' |
Default:
'Dialog'
|
Initial states Value — Initial filter states
0
(default) | scalar | vector | matrix
Specify the initial filter states as a scalar, vector, or matrix. To learn how to specify initial states, see Specifying Initial States.
Dependencies
To enable this parameter, set Initial states
Source to Dialog
.
Programmatic Use
Block Parameter:
InitialStates |
Type: character vector |
Values: scalar | vector | matrix |
Default:
'0'
|
External reset — External state reset
None
(default) | Rising
| Falling
| Either
| Level
| Level hold
Specify the trigger event to use to reset the states to the initial conditions.
Reset Mode | Behavior |
---|---|
None | No reset |
Rising | Reset on a rising edge |
Falling | Reset on a falling edge |
Either | Reset on either a rising or falling edge |
Level | Reset in either of these cases:
|
Level hold | Reset when the reset signal is nonzero at the current time step |
Programmatic Use
Block Parameter:
ExternalReset |
Type: character vector |
Values: 'None' |
'Rising' | 'Falling' |
'Either' | 'Level' | 'Level
hold' |
Default: 'None' |
Input processing — Sample- or frame-based processing
Elements as channels (sample
based)
(default) | Columns as channels (frame based)
Specify whether the block performs sample- or frame-based processing.
Elements as channels (sample based)
— Process each element of the input as an independent channel.Columns as channels (frame based)
— Process each column of the input as an independent channel.Note
Frame-based processing requires a DSP System Toolbox license.
For more information, see Sample- and Frame-Based Concepts (DSP System Toolbox).
Programmatic Use
Block Parameter:
InputProcessing |
Type: character vector |
Values:
'Elements as channels (sample based)' | 'Columns as
channels (frame based)' |
Default:
'Elements as channels (sample
based)' |
Optimize by skipping divide by leading denominator coefficient (a0) — Skip divide by a0
off
(default) | on
When you select this check box, the block does not perform a divide-by-a0 either in simulation or in the generated code. This parameter optimizes your code. An error occurs if you specify the denominator coefficients in the block dialog box and a0 ≠ 1.
If you specify the denominator coefficients from the input port Den, you must select the Optimize by skipping divide by leading denominator coefficient (a0) parameter. When you select this checkbox, the block ignores the leading denominator coefficient a0 and replaces it with a 1.
When you clear this check box, the block is fully tunable during simulation. It performs a divide-by-a0 in both simulation and code generation.
Programmatic Use
Block Parameter:
a0EqualsOne
|
Type: character vector |
Values:
'off' | 'on' |
Default:
'off'
|
Sample time (-1 for inherited) — Interval between samples
-1
(default) | scalar | vector
Specify the time interval between samples. To inherit the sample time, set this
parameter to -1
. For more information, see Specify Sample Time.
Dependencies
This parameter is visible only if you set it to a value other than
-1
. To learn more, see Blocks for Which Sample Time Is Not Recommended.
Programmatic Use
To set the block parameter value programmatically, use
the set_param
function.
Parameter: | SampleTime |
Values: | "-1" (default) | scalar or vector in quotes |
View Filter Response — View filter response
button
Click this button to open the Filter Visualization Tool (fvtool
(DSP System Toolbox)) and display the filter response of the filter
defined in the block dialog box.
Dependencies
To enable this parameter, set the Numerator Source and
Denominator Source parameters to
Dialog
.
This parameter appears only if you have a valid DSP System Toolbox license.
Data Types
State — State data type
Inherit: Same as input
(default) | int8
| int16
| int32
| int64
| fixdt(1,16,0)
| <data type expression>
Specify the state data type. You can set it to:
A rule that inherits a data type, for example,
Inherit: Same as input
A built-in integer, for example,
int8
A data type object, for example, a
Simulink.NumericType
objectAn expression that evaluates to a data type, for example,
fixdt(1,16,0)
The Data Type Assistant helps you set data attributes. To use the Data Type Assistant, click . For more information, see Specify Data Types Using Data Type Assistant.
Programmatic Use
Block Parameter:
StateDataTypeStr
|
Type: character vector |
Values:
'Inherit: Same as input' | 'int8' | 'int16' | 'int32' |
'int64' | 'fixdt(1,16,0)' | '<data type
expression>' |
Default:
'Inherit: Same as input'
|
Numerator coefficients — Numerator coefficient data type
Inherit: Inherit via internal
rule
(default) | int8
| int16
| int32
| int64
| fixdt(1,16)
| fixdt(1,16,0)
| <data type expression>
Specify the numerator coefficient data type. You can set it to:
A rule that inherits a data type, for example,
Inherit: Inherit via internal rule
A built-in integer, for example,
int8
A data type object, for example, a
Simulink.NumericType
objectAn expression that evaluates to a data type, for example,
fixdt(1,16,0)
The Data Type Assistant helps you set data attributes. To use the Data Type Assistant, click . For more information, see Specify Data Types Using Data Type Assistant.
Programmatic Use
Block Parameter:
NumCoefDataTypeStr |
Type: character vector |
Values:
'Inherit: Inherit via internal rule' | 'int8' | 'int16'
| 'int32' | 'int64' | 'fixdt(1,16)' | 'fixdt(1,16,0)' |
'<data type expression>' |
Default:
'Inherit: Inherit via internal rule' |
Numerator coefficient minimum — Minimum value of numerator coefficients
[]
(default) | scalar
Specify the minimum value that a numerator coefficient can have. The
default value is []
(unspecified). Simulink® software uses this value to perform:
Parameter range checking (see Specify Minimum and Maximum Values for Block Parameters)
Automatic scaling of fixed-point data types
Programmatic Use
Block Parameter:
NumCoefMin |
Type: character vector |
Values: scalar |
Default:
'[]' |
Numerator coefficient maximum — Maximum value of numerator coefficients
[]
(default) | scalar
Specify the maximum value that a numerator coefficient can have. The
default value is []
(unspecified). Simulink software uses this value to perform:
Parameter range checking (see Specify Minimum and Maximum Values for Block Parameters)
Automatic scaling of fixed-point data types
Programmatic Use
Block Parameter:
NumCoefMax |
Type: character vector |
Values: scalar |
Default:
'[]' |
Numerator product output — Numerator product output data type
Inherit: Inherit via internal
rule
(default) | Inherit: Same as input
| int8
| int16
| int32
| int64
| fixdt(1,16,0)
| <data type expression>
Specify the product output data type for the numerator coefficients. You can set it to:
A rule that inherits a data type, for example,
Inherit: Inherit via internal rule
A built-in data type, for example,
int8
A data type object, for example, a
Simulink.NumericType
objectAn expression that evaluates to a data type, for example,
fixdt(1,16,0)
The Data Type Assistant helps you set data attributes. To use the Data Type Assistant, click . For more information, see Specify Data Types Using Data Type Assistant.
Programmatic Use
Block Parameter:
NumProductDataTypeStr |
Type: character vector |
Values:
'Inherit: Inherit via internal rule' | 'Inherit: Same
as input' | 'int8' | 'int16' | 'int32' | 'int64' |
'fixdt(1,16,0)' | '<data type
expression>' |
Default:
'Inherit: Inherit via internal rule' |
Numerator accumulator — Numerator accumulator data type
Inherit: Inherit via internal
rule
(default) | Inherit: Same as input
| Inherit: Same as product output
| int8
| int16
| int32
| int64
| fixdt(1,16,0)
| <data type expression>
Specify the accumulator data type for the numerator coefficients. You can set it to:
A rule that inherits a data type, for example,
Inherit: Inherit via internal rule
A built-in data type, for example,
int8
A data type object, for example, a
Simulink.NumericType
objectAn expression that evaluates to a data type, for example,
fixdt(1,16,0)
The Data Type Assistant helps you set data attributes. To use the Data Type Assistant, click . For more information, see Specify Data Types Using Data Type Assistant.
Programmatic Use
Block Parameter:
NumAccumDataTypeStr |
Type: character vector |
Values:
'Inherit: Inherit via internal rule' | 'Inherit: Same
as input' | 'Inherit: Same as product output' | 'int8' |
'int16' | 'int32' | 'int64' | 'fixdt(1,16,0)' | '<data
type expression>' |
Default:
'Inherit: Inherit via internal rule' |
Denominator coefficients — Denominator coefficient data type
Inherit: Inherit via internal
rule
(default) | int8
| int16
| int32
| int64
| fixdt(1,16)
| fixdt(1,16,0)
| <data type expression>
Specify the denominator coefficient data type. You can set it to:
A rule that inherits a data type, for example,
Inherit: Inherit via internal rule
A built-in integer, for example,
int8
A data type object, for example, a
Simulink.NumericType
objectAn expression that evaluates to a data type, for example,
fixdt(1,16,0)
The Data Type Assistant helps you set data attributes. To use the Data Type Assistant, click . For more information, see Specify Data Types Using Data Type Assistant.
Programmatic Use
Block Parameter:
DenCoefDataTypeStr |
Type: character vector |
Values:
'Inherit: Inherit via internal rule' | 'int8' | 'int16'
| 'int32' | 'int64' | 'fixdt(1,16)' | 'fixdt(1,16,0)' |
'<data type expression>' |
Default:
'Inherit: Inherit via internal rule' |
Denominator coefficient minimum — Minimum value of denominator coefficients
[]
(default) | scalar
Specify the minimum value that a denominator coefficient can have. The
default value is []
(unspecified). Simulink software uses this value to perform:
Parameter range checking (see Specify Minimum and Maximum Values for Block Parameters)
Automatic scaling of fixed-point data types
Programmatic Use
Block Parameter:
DenCoefMin |
Type: character vector |
Values: scalar |
Default:
'[]' |
Denominator coefficient maximum — Maximum value of denominator coefficients
[]
(default) | scalar
Specify the maximum value that a denominator coefficient can have. The
default value is []
(unspecified). Simulink software uses this value to perform:
Parameter range checking (see Specify Minimum and Maximum Values for Block Parameters)
Automatic scaling of fixed-point data types
Programmatic Use
Block Parameter:
DenCoefMax |
Type: character vector |
Values: scalar |
Default:
'[]' |
Denominator product output — Denominator product output data type
Inherit: Inherit via internal
rule
(default) | Inherit: Same as input
| int8
| int16
| int32
| int64
| fixdt(1,16,0)
| <data type expression>
Specify the product output data type for the denominator coefficients. You can set it to:
A rule that inherits a data type, for example,
Inherit: Inherit via internal rule
A built-in data type, for example,
int8
A data type object, for example, a
Simulink.NumericType
objectAn expression that evaluates to a data type, for example,
fixdt(1,16,0)
The Data Type Assistant helps you set data attributes. To use the Data Type Assistant, click . For more information, see Specify Data Types Using Data Type Assistant.
Programmatic Use
Block Parameter:
DenProductDataTypeStr |
Type: character vector |
Values:
'Inherit: Inherit via internal rule' | 'Inherit: Same
as input' | 'int8' | 'int16' | 'int32' | 'int64' |
'fixdt(1,16,0)' | '<data type
expression>' |
Default:
'Inherit: Inherit via internal rule' |
Denominator accumulator — Denominator accumulator data type
Inherit: Inherit via internal
rule
(default) | Inherit: Same as input
| Inherit: Same as product output
| int8
| int16
| int32
| int64
| fixdt(1,16,0)
| <data type expression>
Specify the accumulator data type for the denominator coefficients. You can set it to:
A rule that inherits a data type, for example,
Inherit: Inherit via internal rule
A built-in data type, for example,
int8
A data type object, for example, a
Simulink.NumericType
objectAn expression that evaluates to a data type, for example,
fixdt(1,16,0)
The Data Type Assistant helps you set data attributes. To use the Data Type Assistant, click . For more information, see Specify Data Types Using Data Type Assistant.
Programmatic Use
Block Parameter:
DenAccumDataTypeStr |
Type: character vector |
Values:
'Inherit: Inherit via internal rule' | 'Inherit: Same
as input' | 'Inherit: Same as product output' | 'int8' |
'int16' | 'int32' | 'int64' | 'fixdt(1,16,0)' | '<data
type expression>' |
Default:
'Inherit: Inherit via internal rule' |
Output — Output data type
Inherit: Inherit via internal
rule
(default) | Inherit: Same as input
| int8
| int16
| int32
| int64
| fixdt(1,16)
| fixdt(1,16,0)
| <data type expression>
Specify the output data type. You can set it to:
A rule that inherits a data type, for example,
Inherit: Inherit via internal rule
A built-in data type, for example,
int8
A data type object, for example, a
Simulink.NumericType
objectAn expression that evaluates to a data type, for example,
fixdt(1,16,0)
The Data Type Assistant helps you set data attributes. To use the Data Type Assistant, click . For more information, see Specify Data Types Using Data Type Assistant.
Programmatic Use
Block Parameter:
OutDataTypeStr |
Type: character vector |
Values:
'Inherit: Inherit via internal rule' | 'Inherit: Same
as input' | 'int8' | 'int16' | 'int32' | 'int64' |
'fixdt(1,16)' | 'fixdt(1,16,0)' | '<data type
expression>' |
Default:
'Inherit: Inherit via internal rule' |
Output minimum — Minimum value of output
[]
(default) | scalar
Specify the minimum value that the block can output. The default value
is []
(unspecified). Simulink uses this value to perform:
Simulation range checking (see Specify Signal Ranges)
Automatic scaling of fixed-point data types
Programmatic Use
Block Parameter:
OutMin |
Type: character vector |
Values: scalar |
Default:
'[]' |
Output maximum — Maximum value of output
[]
(default) | scalar
Specify the maximum value that the block can output. The default value
is []
(unspecified). Simulink uses this value to perform:
Simulation range checking (see Specify Signal Ranges)
Automatic scaling of fixed-point data types
Programmatic Use
Block Parameter:
OutMax |
Type: character vector |
Values: scalar |
Default:
'[]' |
Lock data type settings against changes by the fixed-point tools — Prevent fixed-point tools from overriding data types
off
(default) | on
Select this parameter to prevent the fixed-point tools from overriding the data types you specify on this block. For more information, see Lock the Output Data Type Setting (Fixed-Point Designer).
Programmatic Use
Block Parameter: LockScale |
Type: character vector |
Values: 'off' | 'on' |
Default: 'off' |
Integer rounding mode — Rounding mode for fixed-point operations
Floor
(default) | Ceiling
| Convergent
| Nearest
| Round
| Simplest
| Zero
Specify the rounding mode for fixed-point operations. For more information, see Rounding Modes (Fixed-Point Designer).
Block parameters always round to the nearest representable value. To control the rounding of a block parameter, enter an expression using a MATLAB® rounding function into the mask field.
Programmatic Use
To set the block parameter value programmatically, use
the set_param
function.
Parameter: | RndMeth |
Values: | 'Floor' (default) | 'Ceiling' | 'Convergent' | 'Nearest' | 'Round' | 'Simplest' | 'Zero' |
Saturate on integer overflow — Method of overflow action
off
(default) | on
Specify whether overflows saturate or wrap.
on
— Overflows saturate to either the minimum or maximum value that the data type can represent.off
— Overflows wrap to the appropriate value that the data type can represent.
For example, the maximum value that the signed 8-bit integer int8
can represent is 127. Any block operation result greater than this maximum value causes
overflow of the 8-bit integer.
With this parameter selected, the block output saturates at 127. Similarly, the block output saturates at a minimum output value of -128.
With this parameter cleared, the software interprets the overflow-causing value as
int8
, which can produce an unintended result. For example, a block result of 130 (binary 1000 0010) expressed asint8
is -126.
Tips
Consider selecting this parameter when your model has a possible overflow and you want explicit saturation protection in the generated code.
Consider clearing this parameter when you want to optimize efficiency of your generated code. Clearing this parameter also helps you to avoid overspecifying how a block handles out-of-range signals. For more information, see Troubleshoot Signal Range Errors.
When you select this parameter, saturation applies to every internal operation on the block, not just the output or result.
In general, the code generation process can detect when overflow is not possible. In this case, the code generator does not produce saturation code.
Programmatic Use
To set the block parameter value programmatically, use
the set_param
function.
Parameter: | SaturateOnIntegerOverflow |
Values: | 'off' (default) | 'on' |
State Attributes
State name — Unique name for block state
''
(default) | alphanumeric string
Use this parameter to assign a unique name to the block state. The default is ' '
. When this field is blank, no name is assigned. When using this parameter, remember these considerations:
A valid identifier starts with an alphabetic or underscore character, followed by alphanumeric or underscore characters.
The state name applies only to the selected block.
This parameter enables State name must resolve to Simulink signal object when you click Apply.
For more information, see C Data Code Interface Configuration for Model Interface Elements (Simulink Coder).
Programmatic Use
Block Parameter: StateName |
Type: character vector |
Values: unique name |
Default: '' |
State name must resolve to Simulink signal object — Require state name resolve to a signal object
off
(default) | on
Select this check box to require that the state name resolves to a Simulink signal object.
Dependencies
To enable this parameter, specify a value for State name. This parameter appears only if you set the model configuration parameter Signal resolution to a value other than None
.
Programmatic Use
Block Parameter: StateMustResolveToSignalObject |
Type: character vector |
Values:
'off' | 'on' |
Default: 'off' |
Block Characteristics
More About
Model Coverage
If you have a Simulink
Coverage™ license, the Discrete Transfer Fcn block receives decision
coverage if you set the External reset block parameter to any
option except for None
. If your model uses a State Control (HDL Coder) block, you cannot
collect coverage for external reset port when the State control
parameter is Synchronous
.
Decision coverage measures a true outcome for time steps where the block resets and a false outcome for time steps where the block does not reset. To receive 100% decision coverage, the block must reset for at least one time step and not reset for at least one time step.
If you select the Saturation on integer overflow (Simulink Coverage) parameter, the Discrete Transfer Fcn block receives saturation on integer overflow coverage. For more information, see Saturate on Integer Overflow Coverage (Simulink Coverage).
Extended Capabilities
C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.
HDL Code Generation
Generate VHDL, Verilog and SystemVerilog code for FPGA and ASIC designs using HDL Coder™.
HDL Coder™ provides additional configuration options that affect HDL implementation and synthesized logic.
This block has one default HDL architecture.
General | |
---|---|
ConstMultiplierOptimization | Canonical signed digit (CSD) or factored CSD optimization. The
default is |
ConstrainedOutputPipeline | Number of registers to place at
the outputs by moving existing delays within your design. Distributed
pipelining does not redistribute these registers. The default is
|
InputPipeline | Number of input pipeline stages
to insert in the generated code. Distributed pipelining and constrained
output pipelining can move these registers. The default is
|
OutputPipeline | Number of output pipeline stages
to insert in the generated code. Distributed pipelining and constrained
output pipelining can move these registers. The default is
|
Native Floating Point | |
---|---|
HandleDenormals | Specify whether you want HDL Coder to insert additional logic to handle denormal numbers in your design.
Denormal numbers are numbers that have magnitudes less than the smallest floating-point
number that can be represented without leading zeros in the mantissa. The default is
|
LatencyStrategy | Specify whether to map the blocks in your design to
|
MantissaMultiplyStrategy | Specify how to implement the mantissa multiplication operation during code generation.
By using different settings, you can control the DSP usage on the target FPGA device.
The default is |
Double data types are not supported for this block. Use single data types instead.
Frame, matrix, and vector input data types are not supported.
The leading denominator coefficient (a0) must be 1 or -1.
Setting the data type as
Inherit: Inherit via internal rule
is not supported.
The Discrete Transfer Fcn block is excluded from the following optimizations:
Resource sharing
Distributed pipelining
PLC Code Generation
Generate Structured Text code using Simulink® PLC Coder™.
Fixed-Point Conversion
Design and simulate fixed-point systems using Fixed-Point Designer™.
This block only supports signed fixed-point data types.
Version History
Introduced before R2006aR2024b: View filter response
Click the View Filter Response button to visualize the frequency response of the filter that you specify in the block dialog box.
R2024a: The Discrete Transfer Fcn block supports variable-size input signals
The Discrete Transfer Fcn block supports variable-size input
signals when you set the Input processing parameter to
Columns as channels (frame based)
.
When the input is a variable-size signal, you can change the frame size (number of rows) of the signal during simulation but the number of channels (columns) must remain constant.
R2023b: Conditional display of the Sample time parameter
The Discrete Transfer Fcn block no longer displays the Sample
time parameter in the block parameters dialog box by default. The
parameter is visible only if you set the sample time to a value other the default
value (-1
) at the command line or in an existing model. For more
information, see Blocks for Which Sample Time Is Not Recommended.
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
Select a Web Site
Choose a web site to get translated content where available and see local events and offers. Based on your location, we recommend that you select: .
You can also select a web site from the following list
How to Get Best Site Performance
Select the China site (in Chinese or English) for best site performance. Other MathWorks country sites are not optimized for visits from your location.
Americas
- América Latina (Español)
- Canada (English)
- United States (English)
Europe
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)
Asia Pacific
- Australia (English)
- India (English)
- New Zealand (English)
- 中国
- 日本Japanese (日本語)
- 한국Korean (한국어)