rfckt.rlcgline
Passive component or network
Description
Use the rfckt.rlcgline object to create a RLCG transmission
line that is characterized by line loss, line length, stub type, and
termination.
Note
txlineRLCGLine is recommended over
rfckt.rlcgline because it enables you to:
Create a RLCG transmission line that is characterized by line loss, line length, stub type, and termination.
Build a
circuitobject with a RLCG transmission line.Model a RLCG transmission line element in an RF chain created using an
rfbudgetobject or the RF Budget Analyzer app, and then export this element to RF Blockset™ or torfsystemSystem object™ for circuit envelope analysis.
(since R2023b)
Creation
Description
h = rfckt.rlcgline returns an RLCG transmission line
object whose properties are set to their default values.
h = rfckt.rlcgline(Name,Value) sets properties using
one or more name-value pairs. For example,
rfckt.rlcgline('LineLength',0.04) creates a RLGC
transmission line with a physical length of 0.04 meters. You can specify
multiple name-value pairs. Enclose each property name in a quote. Properties
not specified retain their default values.
Properties
Object Functions
analyze | Analyze RFCKT object in frequency domain |
calculate | Calculate specified parameters for rfckt objects or rfdata objects |
circle | Draw circles on Smith Chart |
extract | Extract specified network parameters from rfckt object or data object |
listformat | List valid formats for specified circuit object parameter |
listparam | List valid parameters for specified circuit object |
loglog | Plot specified circuit object parameters using log-log scale |
plot | Plot circuit object parameters on X-Y plane |
plotyy | Plot parameters of RF circuit or RF data on xy-plane with two Y-axes |
getop | Display operating conditions |
polar | Plot specified object parameters on polar coordinates |
semilogx | Plot RF circuit object parameters using log scale for x-axis |
semilogy | Plot RF circuit object parameters using log scale for y-axis |
smith | Plot circuit object parameters on Smith Chart |
write | Write RF data from circuit or data object to file |
getz0 | Calculate characteristic impedance of RFCKT transmission line object |
read | Read RF data from file to new or existing circuit or data object |
restore | Restore data to original frequencies |
getop | Display operating conditions |
groupdelay | Group delay of S-parameter object or RF filter object or RF Toolbox circuit object |
Examples
Algorithms
The analyze method treats the transmission line, which can be lossy
or lossless, as a 2-port linear network. It uses the interpolation method you specify in
the IntpType property to find the R, L, C, and G values at the
frequencies you specify when you call analyze. Then, it calculates
the characteristic impedance, Z0, phase velocity, PV, and loss using these interpolated
values. It computes the AnalyzedResult property of a stub or as a
stubless line using the data stored in the rfckt.rlcgline object
properties as follows:
If you model the transmission line as a stubless line, the
analyzemethod first calculates the ABCD-parameters at each frequency contained in the modeling frequencies vector. It then uses theabcd2sfunction to convert the ABCD-parameters to S-parameters.The
analyzemethod calculates the ABCD-parameters using the physical length of the transmission line, d, and the complex propagation constant, k, using the following equations:Z0 and k are vectors whose elements correspond to the elements of f, the vector of frequencies specified in the
analyzeinput argumentfreq. Both can be expressed in terms of the resistance (R), inductance (L), conductance (G), and capacitance (C) per unit length (meters) as follows:If you model the transmission line as a shunt or series stub, the
analyzemethod first calculates the ABCD-parameters at the specified frequencies. It then uses theabcd2sfunction to convert the ABCD-parameters to S-parameters.When you set the
StubModeproperty to'Shunt', the 2-port network consists of a stub transmission line that you can terminate with either a short circuit or an open circuit as shown in the following figure.
Zin is the input impedance of the shunt circuit. The ABCD-parameters for the shunt stub are calculated as:
When you set the
StubModeproperty to'Series', the 2-port network consists of a series transmission line that you can terminate with either a short circuit or an open circuit as shown in the following figure.
Zin is the input impedance of the series circuit. The ABCD-parameters for the series stub are calculated as:
The analyze method uses the S-parameters to calculate the group
delay values at the frequencies specified in the analyze input
argument freq, as described in the analyze
reference page.
References
[1] Ludwig, R. and P. Bretchko, RF Circuit Design: Theory and Applications, Prentice-Hall, 2000
Version History
Introduced in R2009a