Frage
How to continuously repeat the output of the "From Spreadsheet" source block?
Hi, How can I continuously repeat the output of the "From Spreadsheet" source block? The extrapolation at the end does not pro...
etwa 6 Jahre vor | 1 Antwort | 0
1
AntwortFrage
How can I draw a mesh into a block mask/ icon?
Hello, I have a masked Simulink block. Now I want to draw a mesh into the icon. Unfortunately the mesh is drawn into an own w...
fast 9 Jahre vor | 1 Antwort | 0
1
AntwortAutomotive problem - Counting and saving
This depends on your interface to write to the EEPROM. Normally you would count in your RAM and trigger writing to the EEPROM in...
mehr als 9 Jahre vor | 0
How can i change a value of a resistor during simulation using simpowersystems toolbox ( R L C branch )
I had the same requirement. I either use a voltage measurement together with a controlled current source or a current measureme...
mehr als 9 Jahre vor | 0
| akzeptiert
Frage
/usr/bin/ld: raccel_sfcn_utils.o: undefined reference to symbol 'dlclose@@GLIBC_2.2.5'
I get the following message when starting a simulation in rapid acceleration mode under Ubuntu Xenial 64 Bit which works under W...
mehr als 9 Jahre vor | 0 Antworten | 0
0
AntwortenFrage
What is the cause of the error message "FIMATH mismatch:Property 'ProductWordLength'" here?
I get the error message FIMATH mismatch:Property 'ProductWordLength': 16 ~= 32 from the following action code in a stat...
mehr als 9 Jahre vor | 1 Antwort | 0
1
AntwortHow to define the sampling time in a system of Simscape Power System Blocks without accuracy lost importants?
Hi Tony, it's hard to give an advice without knowing your model, simulation settings and the intent of your simulation. Becaus...
mehr als 9 Jahre vor | 0
| akzeptiert
Frage
OutOfMemoryError when building PDF System Design Description for "big" Simulink Model
Hello, I get an OutOfMemoryError when building a System Design Description in PDF and Word format. I already increased the heap...
etwa 10 Jahre vor | 0 Antworten | 0
0
AntwortenFrage
Initial output value for bus in enabled subsystem hierarchy
I have a hierarchy of subsystems where a middle subsystem is an enabled one. The hierarchical subsystems each have a single outp...
etwa 11 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Analyzing and creating fixed-point data types.
Hello, is there a single function to get the minimum and maximum value representable by a specific fixed-point data type? I am ...
fast 13 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Simulink message "Attempt to use invalid data type id 17"
Hello, how can I find out which data type corresponds to a specific id when getting the message "Attempt to use invalid data ty...
mehr als 13 Jahre vor | 1 Antwort | 2
1
AntwortFrage
"Variable time delay" block in "For Each Subsystem"
Hello, I try to synthesize noise coming from multiple targets to multiple sensors. I have two cascaded for-each sub-systems, th...
fast 14 Jahre vor | 1 Antwort | 0