Gain block ignored :

1 Ansicht (letzte 30 Tage)
Doug Bell
Doug Bell am 1 Aug. 2018
Kommentiert: youjarr am 7 Mai 2021
I have a Simulink model with a gain block that has a ToWorkspace before and after, yet the ToWorkspace traces are identical even though the gain has been set to 64, any ideas what may be causing this?
  1 Kommentar
Jim Riggs
Jim Riggs am 1 Aug. 2018
Need more information. What are the settings in each "To Workspace" block?
Variable Name
Data limit
Decimation
Save Format
Sample time

Melden Sie sich an, um zu kommentieren.

Antworten (3)

Fangjun Jiang
Fangjun Jiang am 1 Aug. 2018
The input value to the Gain block is constant zero? Need more info to see the problem.
  2 Kommentare
Doug Bell
Doug Bell am 1 Aug. 2018
thanks Fangjun - it needed a convert datatype block prior to the gain block , it was a Boolean flag toggling between 0 & 1, then multiplied by a power of two, converting to a float before the gain seems to have fixed it
Fangjun Jiang
Fangjun Jiang am 1 Aug. 2018
Without the data type conversion block, the output should still be 64 when the input is boolean true, right?

Melden Sie sich an, um zu kommentieren.


Doug Bell
Doug Bell am 1 Aug. 2018
that was the assumption but it took the datatype conversion block to get what I wanted

youjarr
youjarr am 7 Mai 2021
Hey Guys,
I have an similiar issue.
I have an Signal which is not 0. Then I put an 0 Gain to it... with an parameter which is read from the base workspace.
That value is 0 so I would thing the output of the Signal*0 is 0... but it isn´t it has the value of the signal.
But when I write the 0 directly into the gain hen it works and the output is 0.
The datatype conversion has no effect... .
  2 Kommentare
Fangjun Jiang
Fangjun Jiang am 7 Mai 2021
You are saying that you have a Gain block, its "Gain Value" is a parameter from the base workspace, the value of the parameter is 0, yet, the output of the Gain block is non-zero.
It is strange. I would double check the value of the parameter, the name of the parameter, lower case, upper case, etc.
There is a chance, that there is a parameter with the same name, in the model workspace, its value is non-zero. The variable in the model workspace takes precedent over the base workspace, if their names are the same.
youjarr
youjarr am 7 Mai 2021
You were right. Somehow I saved a value in my model workspace.
Thank you very much.
Have a nice weekend.

Melden Sie sich an, um zu kommentieren.

Kategorien

Mehr zu Programmatic Model Editing finden Sie in Help Center und File Exchange

Tags

Produkte


Version

R2015b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by