Having problems with solver settings and step size in simscape electrical
Hello, I problems with undertanding solver settings and step size in simscape electrical, I attached the model to make it easie...
12 Monate vor | 1 Antwort | 0
1
AntwortFrage
help understand the step size of the electrical engine dyno example
Hello I have a question the the folowing Electric Engine Dyno example ( https://de.mathworks.com/help/sps/ug/electric-engine-dy...
12 Monate vor | 1 Antwort | 0
1
AntwortFrage
difference between "Control sample time " and "Fundamental sample time " for FOC
Hello while Implementing a drive with a Field-oriented-Control i couldn't get the difference between "Control sample time " an...
fast ein Jahr vor | 1 Antwort | 0
1
AntwortFrage
Iterpolation shows wrong results
Hello I have a major problem with my results that I can't seem to find its reason My model beginns with an electrical loads ...
etwa ein Jahr vor | 2 Antworten | 0
2
AntwortenFrage
induction motor response not satisfying
Hello as mentionned the response of the induction motor, its speed, isn't fully as it should be. it's not wrong bet needs adjus...
etwa ein Jahr vor | 1 Antwort | 0
1
AntwortFrage
How to measure the frequency of a 3 phase generator in simscape electrical
Hello I would like to measure the freqeuncy of a 3 phase signal generated by a 3 phase generator in simscape electrical? I did...
etwa ein Jahr vor | 1 Antwort | 0
1
AntwortFrage
unbalanced load on a synchronous generator
Hello, I would like to apply an asymetrical load to a synchronous generator. The original model has 3ph dynamic AC load as sho...
etwa ein Jahr vor | 1 Antwort | 0
1
AntwortFrage
Tuning exciter parameters for a synchronous generator
Hello, I used the following exciter block for synchronous generator for the parameters I used those of an example in simsca...
etwa ein Jahr vor | 1 Antwort | 0
1
AntwortFrage
Implement a Motor drive with constant speed
Hello, for a project I need to implement an induction motor which operats under variable torque while keeping its speed at 1500...
etwa ein Jahr vor | 1 Antwort | 0
1
AntwortFrage
Add a Simscape Multibody model to a Simscape Electrical model
Hello I just found out that you can use a CAD file to generate a Simscape Multibody model, so I wanted to ask if it's possible ...
etwa ein Jahr vor | 1 Antwort | 0
1
AntwortFrage
Parameters of the squirrel cage motor
Hello I need a model of the squirrel cage induction machine for 250kW, 400V and 50Hz but the available models go only up to 160...
mehr als ein Jahr vor | 1 Antwort | 1
1
AntwortFrage
does the rotational port S recognize the load flow?
Hello, for a projct I need to connect an asynchronous motor with a synchronous generator, which will supplement an island grid....
mehr als ein Jahr vor | 1 Antwort | 0
1
AntwortFrage
Understand the inputs of the asynchronous machine
Hello I'm getting started with simscape specialized power systems and I don't get the input for the asynchronous machine in mot...
mehr als ein Jahr vor | 1 Antwort | 0
1
AntwortFrage
Mechanical rotational port of Induction Motor from the specialized power system library
Hello, I want to build a rotary frequency converter using an induction motor and a synchronous generator, connected to each oth...
mehr als ein Jahr vor | 1 Antwort | 0