Frage
Having problems with solver settings and step size in simscape electrical
Hello, I problems with undertanding solver settings and step size in simscape electrical, I attached the model to make it easie...
mehr als ein Jahr vor | 1 Antwort | 0
1
AntwortFrage
help understand the step size of the electrical engine dyno example
Hello I have a question the the folowing Electric Engine Dyno example ( https://de.mathworks.com/help/sps/ug/electric-engine-dy...
mehr als ein Jahr vor | 1 Antwort | 0
1
AntwortFrage
difference between "Control sample time " and "Fundamental sample time " for FOC
Hello while Implementing a drive with a Field-oriented-Control i couldn't get the difference between "Control sample time " an...
fast 2 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Iterpolation shows wrong results
Hello I have a major problem with my results that I can't seem to find its reason My model beginns with an electrical loads ...
fast 2 Jahre vor | 2 Antworten | 0
2
AntwortenFrage
induction motor response not satisfying
Hello as mentionned the response of the induction motor, its speed, isn't fully as it should be. it's not wrong bet needs adjus...
fast 2 Jahre vor | 1 Antwort | 0
1
AntwortFrage
How to measure the frequency of a 3 phase generator in simscape electrical
Hello I would like to measure the freqeuncy of a 3 phase signal generated by a 3 phase generator in simscape electrical? I did...
fast 2 Jahre vor | 1 Antwort | 0
1
AntwortFrage
unbalanced load on a synchronous generator
Hello, I would like to apply an asymetrical load to a synchronous generator. The original model has 3ph dynamic AC load as sho...
fast 2 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Tuning exciter parameters for a synchronous generator
Hello, I used the following exciter block for synchronous generator for the parameters I used those of an example in simsca...
fast 2 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Implement a Motor drive with constant speed
Hello, for a project I need to implement an induction motor which operats under variable torque while keeping its speed at 1500...
fast 2 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Add a Simscape Multibody model to a Simscape Electrical model
Hello I just found out that you can use a CAD file to generate a Simscape Multibody model, so I wanted to ask if it's possible ...
etwa 2 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Parameters of the squirrel cage motor
Hello I need a model of the squirrel cage induction machine for 250kW, 400V and 50Hz but the available models go only up to 160...
etwa 2 Jahre vor | 1 Antwort | 1
1
AntwortFrage
does the rotational port S recognize the load flow?
Hello, for a projct I need to connect an asynchronous motor with a synchronous generator, which will supplement an island grid....
etwa 2 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Understand the inputs of the asynchronous machine
Hello I'm getting started with simscape specialized power systems and I don't get the input for the asynchronous machine in mot...
etwa 2 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Mechanical rotational port of Induction Motor from the specialized power system library
Hello, I want to build a rotary frequency converter using an induction motor and a synchronous generator, connected to each oth...
etwa 2 Jahre vor | 1 Antwort | 0