Simscape Tank (G-TL) Elevation from a reference
The best way may be to use the Pipe (TL) block in Simscape Fluids. Closed conduit that transports fluid between thermal liquid ...
7 Monate vor | 0
Why are my simulink initial conditions sometimes not met, despite high priority?
When selecting Start simulation from steady state, the solver tries to find what the model would go to after a very long simulat...
7 Monate vor | 0
How can I model an Elbow in Simspace while using the TL library?
Elbows are available in the Thermal Liquid library in Simscape Fluids as of R2022a. Pipe turn in a thermal liquid network - MAT...
7 Monate vor | 0
Interface (TL-IL) variable temperature
Thermal liquid elbows have been added as of R2022a. Pipe turn in a thermal liquid network - MATLAB (mathworks.com)
7 Monate vor | 0
Simulate interface between a Thermal Liquid and Two-Phase Fluid
Models heat exchange between a thermal liquid network and a network that can undergo phase change - MATLAB (mathworks.com) A mo...
7 Monate vor | 0
how do I use run-time parameter with simscape gas-charged accumulator
I know that this is an older question. As of a few years ago, all parameters in the Gas-charged Accumulator are run-time capable...
7 Monate vor | 0
How to access to two-phase fluid properties during run
This might be the block that you need: Measure temperature, density, specific enthalpy, specific entropy, and specific volume in...
7 Monate vor | 0
How can I simulate jamming fault at a certain time?
One possibility would be to use the Rotational Damper in Simscape Driveline: Linear rotational damper - MATLAB (mathworks.com) ...
7 Monate vor | 0
Simulink Model DC Motor with Transmission Gear
Please see Vehicle in Simscape Driveline and Simulink - MATLAB & Simulink (mathworks.com). It shows both Simulink and Simscape D...
7 Monate vor | 0
Problems with moving Simscape from 2014b to 2015b
MathWorks does not guarantee behavior when files are saved in a newer release and then opened on an older release. In this case,...
7 Monate vor | 0
Add Reset Function to Simscape Integrator Block
The PS Integrator was updated in R2021a to provide this functionality. The source code is available for that block as well. PS ...
mehr als ein Jahr vor | 0
i want to learn about the oxygen concentrator example in simscape matlab ?
Hello Hassan, You can find information about it here: Oxygen Concentrator - MATLAB & Simulink (mathworks.com)
fast 3 Jahre vor | 0
Negative velocity curve from vehicle body block
Hi Vinay, It is difficult to say what happened, but it looks like recreating the subsystem worked. It may be possible that some...
fast 3 Jahre vor | 0
Source Code Condenser Code
Hi Rainer, A Condenser/Evaporator with two-phase fluid on one side and moist air on the other was introduced in R2019a. A Cond...
fast 3 Jahre vor | 0
Unexpected dog clutch disengagement behavior
Hello Frank, Thank you for including the example model to demonstrate the issue. The translational behavior of the shift link...
mehr als 3 Jahre vor | 1
Unable to open the following model in R2019a trial version.
Hi Sadeer, It looks like the installation is not complete, or the path is incorrect. Definitely contact technical support for...
mehr als 3 Jahre vor | 0
Simple gear model with load dependent efficiency
Hi Mahesh, The load-dependent efficiency model assumes that torque loss is equal to a constant value plus an additional loss ...
mehr als 3 Jahre vor | 0
How is inertia in planetary gear block calculated?
Hello David, Yes, connecting the carrier port would be the carrier inertia. The planet inertia is the sum of all the planet g...
fast 4 Jahre vor | 0
I am getting the following error in simscape driveline please help
Hello Mastrieo, This could be due to an overconstrained model. Check to see if you have conflicting parts of the model, for e...
fast 4 Jahre vor | 0
Thermal behaviour of Harmonic Drive Simulink
Hello Kotryna, Some of this may have been addressed in your other questions. I would also check the Solver Configuration bloc...
fast 4 Jahre vor | 0
Can't find 'Drive Cycle Source' blockset in Simcsape/Simulink.
Hello Rohan, The Drive Cycle Source is part of the Powertrain Blockset. Check to see if you have that product installed. M...
fast 4 Jahre vor | 0
| akzeptiert
"First solve for initial conditions failed to converge." Thermal model
Hello Kotryna, The temperature on those blocks is a difference, not absolute. Also focus on specifying the differential varia...
fast 4 Jahre vor | 0
Initial temperature harmonic drive gear
Hi Kotryana, As a first step, I would look at the Variable Viewer to see what is met and what is not. In the toolstrip, selec...
fast 4 Jahre vor | 0
Generic engine oscillating output
Hi Stephen, This looks like the oscillation is due to the interactions between the slipping pullies in the two belt drives. I...
fast 4 Jahre vor | 0
Quarter model with tire (Magic Formula) SimScape Driveline
Hello Marcin, The H port is a translational conserving port associated with the hub of the tire. It should be associated with...
fast 4 Jahre vor | 0
| akzeptiert
Is it usually used Simscape Driveline for designing the powertrain of a diesel-electric locomotive? Are there any examples about trains?
Hello Stefania, While we do not have any shipping examples regarding trains, users have successfully used Simscape Driveline ...
fast 4 Jahre vor | 0
How can i see the output torque of a gearbox
Hello Sree, If you need the value during simulation, you could add a Torque Sensor from the Simscape Foundation Library in se...
fast 4 Jahre vor | 0
Looking for Leadscrew model in library and not found.
Hello Orlando, Do you have Simscape Driveline installed? This block is in the Simscape Driveline library under Gears and Rota...
fast 4 Jahre vor | 0
| akzeptiert
Torque vector must be arranged in strictly ascending order.
The block is not erroring because of the torque vector given on the Engine Torque tab. Speed is the independent vector that must...
mehr als 4 Jahre vor | 0
Disk Friction Clutch - OPEN clutch
Hello Berkan, There are two types of kinetic friction in the model. The kinetic friction of the clutch plates pushing against...
mehr als 4 Jahre vor | 0