Beantwortet
Electrical Switch doesn't work
You are using an ideal current source set to 1 A. This means that whichever load you attach to it, it will maintain 1A. By open...

etwa 3 Jahre vor | 1

| akzeptiert

Beantwortet
connection port bus for simulink
Connection Ports are different from regular signals which have a data type, can be vectorized with a mux or can be combined in a...

etwa 3 Jahre vor | 0

Beantwortet
Protect a Simulink model but keep the possibility to modify it
You will need the Simulink Coder toolbox.

etwa 3 Jahre vor | 0

| akzeptiert

Beantwortet
How to load matrix variables as constant on Simulink?
Load the .mat file into the Base Workspace of MATLAB, and in Simulink use the From Workspace block to enter the variable name th...

etwa 3 Jahre vor | 0

| akzeptiert

Beantwortet
strcat not supported for code generation simulink
See documentation for the MATLAB Function block. There it is mentioned that: "In addition to language restrictions, the MATLAB F...

etwa 3 Jahre vor | 0

| akzeptiert

Beantwortet
Turn of slider switch automatically
Use a push button instead of a slider switch.

etwa 3 Jahre vor | 0

| akzeptiert

Beantwortet
Simulink custom (non rectangular) Block Shapes
I do not think it is possible to give subsystems an other shape than rectangular. It could conflict with the positioning of the ...

etwa 3 Jahre vor | 1

| akzeptiert

Beantwortet
Compilation of variant subsystem
In a Variant Subsystem, only the active subsystem will be compiled. Any other variants inside the Variant Subsystem will be igno...

etwa 3 Jahre vor | 0

| akzeptiert

Beantwortet
Data type work vector name must less than 31 characters long
Try to increase the setting 'Maximum identifier length' from 31 to 63. It can be found in the Configuration Parameters under 'Co...

etwa 3 Jahre vor | 0

| akzeptiert

Beantwortet
co-simulation within Simulink
I would put each subsystem inside an Enabled subsystem, and enable the second subsystem after the first subsystem had finished a...

etwa 3 Jahre vor | 1

| akzeptiert

Beantwortet
(Matlab) S-function - delayed output
To generate a PWM signal you need to sample much faster than only the switching frequency. You need the higher sample time to be...

mehr als 3 Jahre vor | 0

Beantwortet
Single use switch in Simulink Real-Time
Enabled Subsystem?

mehr als 3 Jahre vor | 0

Beantwortet
Temperature measurement on electrical circuit
When constructing your Simscape Electrical circuit, you will need to enable thermal ports of the relevant components which gener...

mehr als 3 Jahre vor | 0

| akzeptiert

Beantwortet
How to control the CAN transmit Simulink block to send messages on command?
Put the CAN transmit block inside a Triggered subsystem and provide a Boolean with 'true' when you want to send the message. Al...

mehr als 3 Jahre vor | 1

| akzeptiert

Beantwortet
How to get cyber attack models/blocks such as DOS attack, Man in the middle attack in Matlab/Simulink ?
Hi You may want to check the SimEvents package, it is designed to simulate communication and event structures. You can use it t...

mehr als 3 Jahre vor | 0

Beantwortet
Best way to buffer vector data in Simulink for processing over a time window
Using Data Stores would indeed be a solution. However, the dimensions of your matrix increases over time, making it a variable ...

mehr als 3 Jahre vor | 0

| akzeptiert

Beantwortet
How to get multiple axes in floating scope ? There is no axes point out under parameter button.
View -> Layout

mehr als 3 Jahre vor | 0

| akzeptiert

Beantwortet
What is the different between in "Monitor & Tune" and "Build, Deploy & Start" ?
Monitor & Tune means that you just read signals or write parameters to the connected target hardware. The application program ru...

mehr als 3 Jahre vor | 0

Beantwortet
How to display the current value of a TagetPC-Signal in a numeric edit field (App Designer) and update the value automatically every timestep ?
Inside the myTimerFcn, write: app.AEditField.Value = getsignal(tg,'Path',1);

mehr als 3 Jahre vor | 1

| akzeptiert

Beantwortet
How can I generate code for a Matlab function block in Simulink that contains a ''quadprog function''?
See the C/C++ Code Generation notes here. See an example for generating code with quadprog function here.

mehr als 3 Jahre vor | 0

Beantwortet
How to display the current value of a TagetPC-Signal in a numeric edit field (App Designer) and update the value automatically every timestep ?
You need to create a timer object Attach a function call to the timer object Put your code to assign the realtime value to the...

mehr als 3 Jahre vor | 0

Beantwortet
Interpretation of Simulink block warning
You have defined minimum and maximum values of a certain output or signal, and then probably created a vector of it using a Mux ...

mehr als 3 Jahre vor | 1

Beantwortet
How to convert decimal into hexadecimal in "S function" Matlab ?
input = uint16(2748) output = zeros(2,1,'uint8'); output(1) = bitshift(input,-8); output(2) = bitand(input,255); output Hex...

mehr als 3 Jahre vor | 0

Beantwortet
Cell arrays as top-level function outputs are not supported in MATLAB Function Block
The input and output of a MATLAB Function block in Simulink needs to be of a data type supported by Simulink. The data types sup...

mehr als 3 Jahre vor | 0

| akzeptiert

Beantwortet
make a static const variable in generated code with Embedded Coder
In either the Model Workspace or a Data Dictionary linked to your model, create a Simulink.Parameter object and name it "MyNumbe...

mehr als 3 Jahre vor | 0

Beantwortet
Deactivate a switch block once the threshold is achieved.
https://nl.mathworks.com/help/simulink/ug/enabled-subsystems.html

mehr als 3 Jahre vor | 0

Beantwortet
Just want to display the scope's parameters for a period not from 0
Put the Scope block inside an Enabled Subsystem. Use the Digital Clock block to get the simulation time Use Relational Operato...

mehr als 3 Jahre vor | 0

| akzeptiert

Beantwortet
How to run cyclic Simulink block once
Put it inside a Function-call Subsystem and use a function-call signal to trigger it Put it inside a Triggered Subsystem and to...

mehr als 3 Jahre vor | 1

| akzeptiert

Beantwortet
How to input time series in a block parameter in Simulink?
https://nl.mathworks.com/help/simulink/slref/fromworkspace.html https://nl.mathworks.com/help/simulink/ug/load-data-using-the-f...

mehr als 3 Jahre vor | 0

| akzeptiert

Beantwortet
How to stop if else condition after it executes only once.
Put your blocks inside an enabled subsystem, and use the outputs of your if-else block to disable the subsystem itself.

mehr als 3 Jahre vor | 0

Mehr laden