Hello,
I'm back to Simulink after a few years of absence. However, I ran into following warning during simulation, which I've never seen before. And which I still can't interprete after reading it 5 times:
Minimum '-400' and maximum '400' from 'FOC_Controller/PI Controller/U_d' are mapped to a portion of the wide signal coming from 'Output Port 1' of 'FOC_Controller/PI Controller/DQ Limiter/Switch' and have been ignored during range checking. To enable the range checking for the minimum and maximum values, insert a Signal Conversion block with its 'Output' parameter set to 'Signal copy' in front of 'FOC_Controller/PI Controller/U_d'.
Only the bold sentence is unclear to me.
Thanks in advance and greetings,
Thomas
0 Kommentare
Antworten (2)
Jonas
am 8 Jul. 2021
You have defined minimum and maximum values of a certain output or signal, and then probably created a vector of it using a Mux block. The diagnostics complains that that min/max range is only defined for part of the vector signal.
That's my guess, because it's otherwise difficult to assess without seeing your model.