Scope problem in Simulink Desktop Real-Time

I'm trying to modify the van der Pol example of Simulink Desktop real time.
When I add a new scope and connect some variable to plot if i run the simulation the scope does not work or plots random circles.
It seems like it's not able to synchronize to the real-time sync signal.
Is some special setting required when adding a new scope to a real time model?
Image.jpg

 Akzeptierte Antwort

Fangjun Jiang
Fangjun Jiang am 5 Nov. 2019

0 Stimmen

Check if you have a "Marker". On the Scope, View, Style, make sure "Marker" is "none".

1 Kommentar

Thanks! This solved my problem, for some reason Simulink continues to add markers every time I open a scope in a real-time model.

Melden Sie sich an, um zu kommentieren.