Scope problem in Simulink Desktop Real-Time

3 Ansichten (letzte 30 Tage)
Simone Specchia
Simone Specchia am 5 Nov. 2019
Kommentiert: Simone Specchia am 6 Nov. 2019
I'm trying to modify the van der Pol example of Simulink Desktop real time.
When I add a new scope and connect some variable to plot if i run the simulation the scope does not work or plots random circles.
It seems like it's not able to synchronize to the real-time sync signal.
Is some special setting required when adding a new scope to a real time model?
Image.jpg

Akzeptierte Antwort

Fangjun Jiang
Fangjun Jiang am 5 Nov. 2019
Check if you have a "Marker". On the Scope, View, Style, make sure "Marker" is "none".
  1 Kommentar
Simone Specchia
Simone Specchia am 6 Nov. 2019
Thanks! This solved my problem, for some reason Simulink continues to add markers every time I open a scope in a real-time model.

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by