Simulink Real-Time CPU overload in standalone mode

9 Ansichten (letzte 30 Tage)
Alex Austin
Alex Austin am 12 Apr. 2019
Kommentiert: Alex Austin am 4 Sep. 2020
Hi,
Using 2017B and a Speedgoat Mobile Real Time Target machine we are seeing CPU overload errors when built and run in standlone mode, but exactly the same model built and run in normal (DOS loader) mode runs fine with no overloads. The model is an automotive controller using CAN and UDP connectivity (no phyiscial I/O).
Anyone got any ideas where to investigate more to understand this problem?
Thanks.
  3 Kommentare
Wenjie Chen
Wenjie Chen am 21 Aug. 2020
I have encouter the same issue. Got any solution already?
Alex Austin
Alex Austin am 24 Aug. 2020
Sorry no - recently tried same experiment on R2020a version and same result.
I've basically given up on the standalone mode - I just think that not many people use it, and consequently they don't really maintain or develop it as well as they could.

Melden Sie sich an, um zu kommentieren.

Antworten (1)

Ivo Houtzager
Ivo Houtzager am 1 Sep. 2020
I had the same issue. For me disabling "USB Support" in the target settings solved it.
Also the disable SMI block from https://de.mathworks.com/matlabcentral/fileexchange/18832-disabling-smis-on-intel-r-ich5-chipsets works well if you have a supported chipset.
  1 Kommentar
Alex Austin
Alex Austin am 4 Sep. 2020
Thanks for the ideas - I'll give them a go and let you know if it works

Melden Sie sich an, um zu kommentieren.

Produkte


Version

R2017b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by