Thermal Liquid Tank in simscape
6 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
I need to use a Tank (thermal liquid container) in Simscape with more than three inlets/outlets ports; in fact by editing the "Block choices" you can reach no more than three inlets. The only solution i have think till now is to link two Tanks, each one made by three ports in order to reach four ports; in this way by linking other Tanks (with three ports each one) to the previous ones we gain a free ports and so on. Anyway i don't think this is the most efficient way to get a Tank with more than three inlets/outlets. Can anyone help me?
0 Kommentare
Antworten (1)
Yifeng Tang
am 28 Sep. 2022
I don't think there is a more easy or efficient way in your case.
In the latest version of Simscape, however, you can get up to 6 inlets :-)