cification voltgae=50,max speed=10000 RPM, fulx Linkage=0.00459,Motor Poles=22,Internal Resistance =0.016, D-Q axis inductance=0.000015 mH,interia=0.0000231 .when i operate at the low frequeny 10 volt it works fine, at higher frequency it is making oscillation in the volatge current torque and speed.(No control Method is used here, just purely mathematical model and supply voltage and theta as the feedback to the clark and park transfromation )

1 Kommentar

John D'Errico
John D'Errico am 30 Dez. 2025
Bearbeitet: John D'Errico am 30 Dez. 2025
What is your question? (About MATLAB!) Are you surprised that something oscillates, or goes unstable? That can happen easily enough. Not only that, but we have no knowledge that what you even did was correct in terms of code, since we cannot see inside your computer, and you show no code. So what are you asking? What can you expect for an answer here?

Melden Sie sich an, um zu kommentieren.

 Akzeptierte Antwort

Dinesh
Dinesh am 9 Jan. 2026

0 Stimmen

I have assumed the Linear Magnetic model with a balanced three-phase system and used the parameters you provided. I did not observe any oscillations; there is some transient behavior initially, but the system reaches a steady state afterward.

2 Kommentare

Rangappa
Rangappa am 9 Jan. 2026

Please revert toady with screen shot because as I am thinking at higher frequency the theta feedback is not aligning with Clark and park transform leads to the continues oscillations.but when we used low interia value it directs aligns with Clark and park transforms and it reaches the steady state .you just enter the electrical frequency in the supply volatge.and 0.000231 as the interim value it will give oscillations

Rangappa
Rangappa am 9 Jan. 2026

Just change the interia to 0.000231 kg.m2

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (1)

Rangappa
Rangappa am 9 Jan. 2026

0 Stimmen

Just change the interia to 0.000231 kg.m2

1 Kommentar

Rangappa
Rangappa am 9 Jan. 2026

Please revert toady with screen shot because as I am thinking at higher frequency the theta feedback is not aligning with Clark and park transform leads to the continues oscillations.but when we used low interia value it directs aligns with Clark and park transforms and it reaches the steady state .you just enter the electrical frequency in the supply volatge.and 0.000231 as the interim value it will give oscillations

Melden Sie sich an, um zu kommentieren.

Kategorien

Mehr zu Specialized Power Systems finden Sie in Hilfe-Center und File Exchange

Gefragt:

am 30 Dez. 2025

Kommentiert:

am 9 Jan. 2026

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by