- Increase the inverter switching frequency (in the example 2 kHz is used) and reduce the fundamental sample time. This will slow down the simulation, but we should see less ripple from the discretization. Controllers will need retuning as well.
- Re-tune the controllers so that they meet your specific requirements. Check this example if you’re considering using the PID autotuner block: https://www.mathworks.com/help/slcontrol/ug/tune-field-oriented-controllers-for-a-pmsm-using-closed-loop-pid-autotuner-block.html
PMLSM Controller Over Active
5 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
I started with the three phase PMLSM example: https://www.mathworks.com/help/sps/ug/three-phase-pmlsm-drive.html . I modified the outer control loop so that it regulates to a velocity set point instead of tracking position. The output scope capture shows that after some initial overshoot and undershoot it is able to maintain 0.5 m/s and then 0 m/s when a step change in the setpoint changes. However, the controller appears to be over active and the thrust and phase currents appear extremely noisy. Can someone give me some tips are troubleshooting steps to determine how to smooth out the control effort? Thank you.
0 Kommentare
Akzeptierte Antwort
Sabin
am 8 Aug. 2025
There are a few things you can try.
Weitere Antworten (0)
Siehe auch
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!