Naming signal in simulink based on workspace variable value.

3 Ansichten (letzte 30 Tage)
IPro
IPro am 4 Mai 2023
Bearbeitet: Fangjun Jiang am 8 Mai 2023
In simulink, I would like to set the signal names based on the string values contained in a workspace variable.
Example:
In the out.simout field, I get two subfields named "signal1" and "signal2". Instead, I would like them to be named based on the string values contained in a workspace variable.
Is there any solution to this? Thanks!
PS: A simple workaround would be to name manually the two step signals in the Simulink model. Then, the out.simout fields would inherit the names defined in simulink. However, this is not convenient when there are multiple signals.
  2 Kommentare
Fangjun Jiang
Fangjun Jiang am 4 Mai 2023
Don't understand your question. Assume your have a="string1", b="string2" in workspace. You have to associate them with the two blocks in Simulink. In terms of the amout of work, that is the same as labeling the two signal lines as "string1" and "string2".
Are you asking if you could type in a, instead of "string1" in case the string is really long?
IPro
IPro am 5 Mai 2023
Indeed. I would like to use the variable name,e.g. "a" in your example, which contains the string "string 1". That's convenient, especially if e.g. there are many signals bundled together, whose desired names are saved in a variable, e.g.
a = [{'string1', 'string2', 'string3'];

Melden Sie sich an, um zu kommentieren.

Antworten (1)

Fangjun Jiang
Fangjun Jiang am 5 Mai 2023
It can't be done like a numerical parameter, where you can type in e.g. pi, instead of 3.1415926535
But it can be done through a script. Do a for-loop for multiple blocks/signal lines.
lh=get_param('PathToBlock','LineHandles');
line=lh.Outport;
set_param(line(1),'Name','ThisIsMySignalName')
or
a = {'string1', 'string2', 'string3'};
set_param(line(1),'Name',a{1});
  2 Kommentare
IPro
IPro am 8 Mai 2023
Thanks for the answer. Your solution sets the name of the Simulink line, but not the name of the signals contained in that line. I would like to change the name of the signals instead.
Fangjun Jiang
Fangjun Jiang am 8 Mai 2023
Bearbeitet: Fangjun Jiang am 8 Mai 2023
That is confusing. The name of the line IS the name of the signal. You have to provide an example to clarify it.

Melden Sie sich an, um zu kommentieren.