Hi All,
How can I input an efficiency map instead of a fixed value parameter for the fixed-displacement hydraulic pump model in simhydraulics?
Any ideas?
1 Kommentar
Junfei Tang
am 4 Feb. 2016
You can have a look at this. I guess it might be similar to your issue: http://www.mathworks.com/matlabcentral/answers/44515#answer_208604
Antworten (1)
Yifeng Tang
am 16 Jun. 2022
In newer versions of Simscape Fluids, the fixed-displacement pumps allow lookup tables as inputs to specify the efficiency as a function of pressure gain and rpm.
If those are not available to you, the way to implement this manually is via lookup table outside ideal source blocks. A diagram like below can be a starting point. It only cover the volumetric efficiency part and requires RPM as a signal input.
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1034500/image.png)
If you want to couple it with the mechanical domain, as in the fixed-displacement pump block, you may add a torque source and a velocity sensor for that purposes. The input to the torque source will be calculated from the delta_P and mechanical efficiency lookup table. The output from the velocity sensor will be sent to the "pump".
0 Kommentare