How can I connect 3 Simscape ports programmatically

3 Ansichten (letzte 30 Tage)
Ferdinand Grimm
Ferdinand Grimm am 14 Jan. 2022
Beantwortet: Timo Dietz am 14 Jan. 2022
Hello everyone,
Recently I am having a simulink problem:
I would like to connect 3 Simscape Electrical Ports programmatically.
The result should look something like this:
For that I wrote a MATLAB Code that should create the above:
simulink
open_system(new_system('sys'));
% Add Blocks
add_block('nesl_utility/Connection Port','sys/1');
add_block('nesl_utility/Connection Port','sys/2');
add_block('ee_lib/Passive/Capacitor','sys/C');
% Move Blocks
set_param('sys/1','position',[0,0,30,30]);
set_param('sys/C','position',[0,100,30,130]);
set_param('sys/2','position',[0,200,30,230]);
% Find Position
par1 = get_param('sys/1','PortConnectivity');
parC = get_param('sys/C','PortConnectivity');
par2 = get_param('sys/2','PortConnectivity');
pos1 = par1.Position;
posC1 = parC(1).Position;
posC2 = parC(2).Position;
pos2 = par2.Position;
% Connect Blocks
add_line('sys', [pos1;posC1]);
add_line('sys', [pos2;posC2]);
add_line('sys', [pos1;pos2]);
The problem is, that one connection is always missing, and with the above code I get this:
Is there any solution for this?

Akzeptierte Antwort

Timo Dietz
Timo Dietz am 14 Jan. 2022
Hello,
you can directly connect via the port pin names, instead of using the position information:
add_line('sys', '1/RConn1', 'C/LConn1')
add_line('sys', '2/RConn1', 'C/RConn1')
add_line('sys', '1/RConn1', '2/RConn1')

Weitere Antworten (0)