Aggregate Equivalent Length of Local Resistances (AELoLR) Simscape hyd. Pipes
3 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Hi there,
I am struggeling a bit with the concept of AELoLR in the Simscape Hyd. Domain.
Since L_eq = K (D/f) where K is the minor loss coeff. and D is the diameter of the pipe (both given) how to get f ((Moody) Friction Factor) for a specific Regime (lam., trans. or turb)?
I unterstood the link: f = e/D, with e = rougthness for complete turbulence, but what if this is going to change to laminar?
thankful for all help and information!
0 Kommentare
Antworten (1)
Yifeng Tang
am 20 Jul. 2022
Hi Michael,
This parameter is there to add some length to the pipe only in the equations that calculate the friction loss, see documentation here. It uses the same friction factor computed from the Haaland approximation or the specified value for laminar regime or a blend of these two values. This "length" doesn't add any volume to the pipe. It's designed to model minor additional losses like some bend in the pipe, connection losses, etc., without using an extra block. It's best tuned if you have pressure loss and flow data over the pipe.
0 Kommentare
Siehe auch
Kategorien
Mehr zu Two-Phase Fluid Library finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!