Frage
How to save harmonic datas so that I can save it as a table with harmonic order Vs magnitude from FFT Analysis in POWER GUI in simulink?
I want to tabulate harmonic values which i got from FFT analysis. How can i do that. In figure, in axes properties i cannot copy...
mehr als 8 Jahre vor | 0 Antworten | 0
0
AntwortenDerivative input is Inf
Error with attached model. # Use 0.000000001 or so instead of 0 in Integrator initial condition box. Try reducing or increasi...
mehr als 8 Jahre vor | 0
| akzeptiert
How do I solve/avoid this error?
Add "unit delay" blocks in front of the "errored" blocks
mehr als 8 Jahre vor | 0
how to solve this problem?
If possible submit ur model or mail it . Check mux/demux input/output signal numbers
mehr als 8 Jahre vor | 0
| akzeptiert
Frage
What is the error with this attached Phase Locked Loop(PLL)?
In scope 13 why its not synchronised? What should i do to make it synchronised?
mehr als 8 Jahre vor | 0 Antworten | 0
0
AntwortenFrage
How will i know that my Phase Locked Loop(PLL) is working fine?
I applied a 230V 50Hz three phase ac supply. Outputs are omega(w) and theta(by integrating omega). What should be the wave shape...
mehr als 8 Jahre vor | 1 Antwort | 0
1
AntwortFrage
How can i use below m-file in simulink using look up table?
Please see the attachment and give a detailed step or even a look-up table for above data if possible.
mehr als 8 Jahre vor | 0 Antworten | 0
0
AntwortenFrage
Why am i not able to control DC Link voltage in the attached mdl files?
I need to regulate dc link voltage for whatever dc reference im giving. But I dont know why i not getting. When i am giving 100 ...
mehr als 8 Jahre vor | 0 Antworten | 0
0
AntwortenHow to limit the current DC-DC Buck Converter
U should enable limiter inside PI controller block.
mehr als 8 Jahre vor | 0
| akzeptiert
Why do I receive an error while connecting resistor and capacitor?
Submit ur model
mehr als 8 Jahre vor | 0
Simulink space vector PWM simulation
Please resubmit ur valid mdl file or send me at tpfasil2007@gmail.com
mehr als 8 Jahre vor | 0
| akzeptiert
Frage
Why I am not able to get dc link voltage as 200? Please help with proper explanation. Kp and Ki values used are based on a calculation.
I am a newbie in control part. Ive tried PI tuning option in simulink(not sure whether its correct), but it was a failure since ...
mehr als 8 Jahre vor | 0 Antworten | 0
0
AntwortenSimulink space vector PWM simulation
Try with abc-AlphaBeta simulink block. Or submit ur mdl file
mehr als 8 Jahre vor | 0
Frage
What is the purpose of using 1.2 here in sine pwm. In space vector pwm i saw source voltage divided by 1.8. Why is it used? For what purpose?Please explain with sufficient theory
http://www.mathworks.com/matlabcentral/fileexchange/28536-three-phase-sinosoidal-pwm-based-rectifier
mehr als 8 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Why cant i tune this simple electrical system? "The plant model in the PID loop linearizes to zero" Please help!!!!!!!!!!!!!!!!!!!!!!!!!!!
I am using 3 PI controllers in "Subsystem". When i used Kp and Ki values given in a paper im getting horiible results. So i trie...
mehr als 8 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Why cant i tune this simple electrical system? "The plant model in the PID loop linearizes to zero" Please help!!!!!!!!!!!!!!!!!!!!!!!!!!!
I am using 3 PI controllers in "Subsystem". When i used Kp and Ki values given in a paper im getting horiible results. So i trie...
mehr als 8 Jahre vor | 1 Antwort | 0
1
AntwortFrage
How to add a 1/z delay block in SVPWM-2 level block. It showing attempting to modify configurable sub library.
Ive tried control+L and dragging pasting etc etc. But unabel to save..permission denied is being shown. please help
mehr als 8 Jahre vor | 0 Antworten | 0
0
AntwortenWhy do I get an Algebraic Loop error when I do not have any algebraic loops in Simulink 6.0 (R14)?
https://www.mathworks.com/videos/algebraic-loop-highlighting-99899.html
mehr als 8 Jahre vor | 0
solve a Heat ex changer question and its showing it has a Algebraic Loops error
http://www.mathworks.com/videos/algebraic-loop-highlighting-99899.html
mehr als 8 Jahre vor | 0
Frage
Why am i getting these many errors while simulating. Please help me by rectifying these errors and also by explaining reason for those errors
Im trying to simulate the attached system and when im trying to run the system its showing some types of errors all the time. No...
mehr als 8 Jahre vor | 1 Antwort | 0
1
AntwortSample time in Simulink
Hi there! The sample time after propagation is [0, 0]. Enter a discrete sample time in 'Current_PI/Integrator'. What is th...
mehr als 8 Jahre vor | 0
Discrete PID Controller / Sampling times must agree
Hi Arkadiy Turevskiy, I am new to controllers.So I modelled a system first, and when i tried tuning , it showed " The sampl...
mehr als 8 Jahre vor | 0
Gesendet
MULTIMACHINE MATLAB PROGRAM FOR WSCC CLASSICAL 9 BUS SYSTEM
MULTIMACHINE MATLAB PROGRAM FOR WSCC CLASSICAL 9 BUS SYSTEM
mehr als 8 Jahre vor | 11 Downloads |
Frage
Simulink cannot unify the dimensions of the multiplexed signal at output port 1 of 'Mux1' to match the input dimension of input port 1 of 'Selector'. Specifically, Simulink cannot unify {[-1],1}
Hi there! In the attached image, how can i provide just d and q component by avoiding 0 component to "dq0/abc" block.
mehr als 8 Jahre vor | 0 Antworten | 0