R2020b : coverage explorer cumulative data
Hi Nicolas, You can aggregate coverage results programmatically using the + operator. You can find more details in this example...

ein Tag vor | 0

Beantwortet
How to determine the subset of a test suite which needs to be rerun due to changes to a project's codebase?
I recommend you take a look at the CI/CD Automation support package: https://www.mathworks.com/products/ci-cd-automation.html O...

3 Monate vor | 0

Beantwortet
How Generate Code Coverage Report in Cobertura XML Format for a .slx file
Hi Diana, For Simulink models you can use the sltest.plugins.ModelCoveragePlugin. This documentation page has an example of how...

4 Monate vor | 0

| akzeptiert

Beantwortet
test harness input for "read from file"
Hi Bertug, As you are using image files, you need to use the "Parameter Overrides" section to change the name of the image you ...

5 Monate vor | 0

Beantwortet
Load nonfinite (Inf or NaN) data into simulink simulation
The only way that I know of to bring in NaN and Inf data into Simulink is with the Playback block, available starting in R2022b:...

5 Monate vor | 0

Beantwortet
Multi-Dimension Matrix input for Simulink Test R2022a
Yes, you can create multidimensional signals in the Signal Editor. In your data, every column is treated as a separate "sub"-sig...

6 Monate vor | 0

Gelöst


Determine whether a vector is monotonically increasing
Return true if the elements of the input vector increase monotonically (i.e. each element is larger than the previous). Return f...

8 Monate vor

Beantwortet
How can I measure Equivalence Class Coverage for a Simulink model?
Measuring Equivalence Class Coverage is not natively supported in Simulink Coverage, but we have developed an intial solution fo...