Tejas Rivonkar
Followers: 0 Following: 0
Statistik
RANG
145.702
of 295.467
REPUTATION
0
ANTWORTZUSTIMMUNG
30.0%
ERHALTENE STIMMEN
0
RANG
of 20.234
REPUTATION
N/A
DURCHSCHNITTLICHE BEWERTUNG
0.00
BEITRÄGE
0 Dateien
DOWNLOADS
0
ALL TIME DOWNLOADS
0
RANG
of 153.912
BEITRÄGE
0 Probleme
0 Lösungen
PUNKTESTAND
0
ANZAHL DER ABZEICHEN
0
BEITRÄGE
0 Beiträge
BEITRÄGE
0 Öffentlich Kanäle
DURCHSCHNITTLICHE BEWERTUNG
BEITRÄGE
0 Highlights
DURCHSCHNITTLICHE ANZAHL DER LIKES
Feeds
Frage
How inrush current related to saturation characteristics of transformer block ?
when i am simulating a system for inrush current, unless and until the transformer block is set in saturable condition it won't ...
fast 5 Jahre vor | 0 Antworten | 0
0
AntwortenFrage
How do I generate a variable in work space for the sample time which Simulink uses for simulation to be used in a code?
clc format short %tout: a vector of number. The below removes numbers that are not multiple of 0.00005 tol = 1e-14; %abritra...
fast 5 Jahre vor | 1 Antwort | 0
1
AntwortFrage
How to generate a variable for step size of Powergui in the workspace?
clc format short %tout: a vector of number. The below removes numbers that are not multiple of 0.00005 tol = 1e-14; %abr...
fast 5 Jahre vor | 0 Antworten | 0
0
AntwortenFrage
how to get the sampling frequency from powergui as variable in workspace?
clc; tout = [0;3.46876101232481e-08;2.08125660739489e-07;1.07531591382069e-06;5.41126717922670e-06;2.70910235062568e-05;5.00000...
fast 5 Jahre vor | 0 Antworten | 0
0
AntwortenFrage
Need help to delete garbage values from a Matrix
% Create the .dat file clc format short tout1=tout; tout2=tout; r=size(tout1); n=r(1,1); for i=2:n if mod(tout1(...
fast 5 Jahre vor | 1 Antwort | 0
1
AntwortRed dotted line problem in simulink?
That because you are trying to connect to two blocks which belong to two different domains. try PS-simulink converter or simuli...
fast 5 Jahre vor | 0
Frage
How to generate COMTRADE file from simulink simulations?
% Create the .dat file clc format short NS1 = size(tout); % to find the number of samples NS2 = NS1(1,1)...
fast 5 Jahre vor | 0 Antworten | 0
0
AntwortenFrage
GUI to interface Matlab with Omicron (Significance of the syntex used)
invoke(test, 'CMDevlock', hEngine, Info2(1)') what is the difference between the above code and the one below? invoke(test, 'C...
fast 5 Jahre vor | 1 Antwort | 0
1
AntwortFrage
How to interface a Simulink block with slider button on GUI?
% function for the "slider" Load Active Power % % The slider value is passed on the "edit text" box % function ldR_Callback(hO...
fast 5 Jahre vor | 0 Antworten | 0
0
AntwortenFrage
how to create an interface matlab with omicron
test = actxserver('omicron.cmengine.1') [Number , Version] = invoke (te...
fast 5 Jahre vor | 0 Antworten | 0
0
AntwortenFrage
why there is a voltage drop across the secondary side of the transformer from other of the theoretical values in simulink?
the secondary output of the simulated three phase balanced system with transformer in simulink shows different values then the t...
etwa 5 Jahre vor | 1 Antwort | 0