Beantwortet
Implementation of two-phase liquid out of REFPROP into simscape
In the same Documentation page, there is an example of using the same command to assign the properties to a Two-Phase Fluid Prop...

mehr als 2 Jahre vor | 0

| akzeptiert

Beantwortet
How can I solve the error generated by a T-Junction when there is a Parallel Channels block in my simscape fluid model?
Hi Miguel, In the model you shared, the T-junction has the default initial flow target of 0 at all ports and "high" priority. ...

mehr als 2 Jahre vor | 2

Beantwortet
Data center Simscape modelling
There is a shipping example on data center cooling, in R2023a. https://www.mathworks.com/help/hydro/ug/data-center-cooling.html...

mehr als 2 Jahre vor | 2

Beantwortet
Fin Surface Area Condenser-Evaporator (2P-MA) Simscape Fluids
In the parameter dialog, the fin area for the MA side are for those thin foil/sheet you see on the outside of the tubes. The wa...

mehr als 2 Jahre vor | 1

| akzeptiert

Beantwortet
Cooling system whit Ammonia not run
Hi Francesco, We believe the error has to do with the fact that NH3 has a non-monotonic supercritical line. It needs to be fix...

mehr als 2 Jahre vor | 0

Beantwortet
Error using System-Level Refrigeration Cycle (2P)
Hi Carlo, We believe the error has to do with the fact that NH3 has a non-monotonic supercritical line. It needs to be fixed i...

mehr als 2 Jahre vor | 0

Beantwortet
Simscape two-phase fluid in closed accumulator looses pressure
Hi Patrick, I believe what you are seeing is the result of the "upwind energy scheme" implemented at all ports of thermo-fluids...

mehr als 2 Jahre vor | 1

| akzeptiert

Beantwortet
how mixing pressure Pm is calculated in gas ejector model of Matlab
This pm term is EVERYWHERE in the governing equations of the ejector. It's solved for implicitly to keep the system of equation...

mehr als 2 Jahre vor | 1

Beantwortet
How to model actuator ports in Simscape fluids?
I'd encourage you to think more about the "effect" of a port in the actual system, instead of just having the actually values of...

mehr als 2 Jahre vor | 0

Beantwortet
issues on Heat exchanger in simscape TL-MA
Setting reasonable parameters to discribe the nominal conditions for the heat exchanger seem to resolve the issue. Pay particul...

fast 3 Jahre vor | 0

| akzeptiert

Beantwortet
In a Simscape Fluids/Hydraulic/IL centrifugal pump model, why is the flow higher after narrow pipe than directly after the pump?
In the Isothermal Liquid domain, the density of the fluid is a function of the pressure. See this documentation page: https://w...

fast 3 Jahre vor | 3

| akzeptiert

Beantwortet
How can I mode the refrigeration cycle considering frosting in the evaporator in simscape
Hi Shuping, You are correct about the condensed water being removed right away (like magic) from the MA domain. Therefore, no ...

fast 3 Jahre vor | 0

Beantwortet
Modelling a layer of water crossed by a water circulation.
Hi Lucas, Check out the attached modified .ssc file and a simple test harness. I keep most of the equations from constant volu...

fast 3 Jahre vor | 0

| akzeptiert

Beantwortet
problem with ssc_build to generate custom simscape library
The input to the ssc_build command should be the directory name, instead of the .ssc file name. The directory can contain multi...

fast 3 Jahre vor | 0

| akzeptiert

Beantwortet
Two-Phase Cascade Heat Exchanger
Suggestion: check the parameters you've set for the heat exchanger, source, and reservoir blocks. Pay special attention to the ...

fast 3 Jahre vor | 0

| akzeptiert

Beantwortet
Modelling a layer of water crossed by a water circulation.
For the thermal liquid and almost all other fluids domains, you'll see a "port_convection" connection in the component block. C...

fast 3 Jahre vor | 0

Beantwortet
variation of liquid and gas over time and the pressure variation inside a tank
The two absoluate reference block I believe will enforce the temperature and pressure to be 0K and 0Pa, respectively. Use Cap i...

fast 3 Jahre vor | 0

| akzeptiert

Beantwortet
Increase power compressor 2 phases simscape
Scale up the mass flow lookup table inside the compressor map block. You will then get more flow for the same RPM and pressure ...

fast 3 Jahre vor | 0

Beantwortet
Can T-Junction (IL) be used to merge 2 pipe flows?
Yes, sure, although it's not necessary if you just want to merge two flows. You may just connect both B ports to the next compo...

fast 3 Jahre vor | 0

| akzeptiert

Beantwortet
Calculating Work done by a Closed Cylinder in Simulink and Simscape
You mentioned that you are using Simscape for the simulation of the cylinder. If that is indeed the case, I believe it would be...

fast 3 Jahre vor | 0

| akzeptiert

Beantwortet
What causes the pressure to be different in the shown figure when I use flow divider which must be dividing the flow equally?
The pressure sensor is an across variable sensor and no flow will go through the block. So your motor isn't getting any fluid t...

fast 3 Jahre vor | 0

| akzeptiert

Beantwortet
Which blocks could I use to model a hydraulic turbine in Simscape?
Some ideas: This hydraulic motor may be useful, though I suspect the shape of its performance curve may not be like that of a t...

fast 3 Jahre vor | 0

Beantwortet
TL pressure Keep descending until the error is reported below the minimum effective value in matlab "official example of heat pump"
It's a model problem, in my opinion, meaning some important feature is missing from the model. In this case, some type of tank ...

etwa 3 Jahre vor | 0

Beantwortet
Does simscape two-phase element "2P pipe" allows constant temperature , constant pressure and constant mass flow rate as inputs?
The source block is only responsible of driving a flow. The states, temperature and/or pressure, are set mainly by the conditio...

etwa 3 Jahre vor | 0

Beantwortet
Pump system Thermal Liquid Modeling for Liquid Cooling
I noticed that the sensors in the model appear to be placed incorrectly. For through variable (flowrate, current, heat flux) ...

etwa 3 Jahre vor | 0

Beantwortet
Hydraulic Actuators in Series
There is a setting in the converter block about whether pressure in the volume causes the R port to move in positive or negative...

etwa 3 Jahre vor | 0

Beantwortet
Blower modeling in Simscape
In both the Gas and Moist Air domains, there is a Fan block you may try to use to model a blower. If Gas domain is sufficient f...

etwa 3 Jahre vor | 0

Beantwortet
Create a blockage in a pipe and simulate in Simulink
HI Adeyemi, The easiest thing to do is to use a Variable Local Restriction and closes it when you want the blockage to occur. ...

etwa 3 Jahre vor | 0

Beantwortet
positive displacement compressor (G) for simulating roots blower
Looks like this positive displacement compressor would be the right choice. A roots-type blower indeed works by trapping a fixe...

etwa 3 Jahre vor | 0

| akzeptiert

Beantwortet
SimScape Tank (G-TL) - Liquid below inlet height error
This error is saying your liquid level is too low. Since it happened after the simulation has run for 22 secs, either too much ...

etwa 3 Jahre vor | 0