Bypassing the internal (Linear) observer in MPC toolbox 3

1 Ansicht (letzte 30 Tage)
Qadeer Ahmed
Qadeer Ahmed am 16 Jun. 2011
Bearbeitet: Bill Tubbs am 24 Mai 2021
I wish to use my designed non-linear Observer with the MPC block (MPC toolbox v3.1)for the real-time control of a system. However, the MPC block contains its own linear observer for state estimation.
How can I bypass (disable) the internal linear observer of the MPC block in Simulink for real-time implementation.

Antworten (1)

Bill Tubbs
Bill Tubbs am 24 Mai 2021
Bearbeitet: Bill Tubbs am 24 Mai 2021
Might be 10 years too late but I had this question and it looks like you can set the following check box below in the Simulink MPC block parameters:
When I did this, the usual 'measured output' inport is replaced with an inport labelled `x[k|k]` for the state estimates from some other observer.
[I'm using MATLAB 2019b.]

Kategorien

Mehr zu Explicit MPC Design finden Sie in Help Center und File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by