How can I specify a serial terminator > 127?
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
I am implementing serial communications specified in ICOM Communications Interface - V ver 3.2. I do not get an error number.
Each CI-V message begins with 'FEFE' [254 254] and terminates with 'FD' (253). Actual serial communications is in decimal. A typical message would look like:
['FE';'FE';'E1';'E0';'03';'FD'] or
[254
254
225
224
3
253] as actually transmitted.
Is there a way to specify a 253 ('FD') terminator? If not, can you suggest a method to have the BytesAvailableFcn trigger on the 253 ['FD']?
serial object specified in Methods:
obj.serialObj = serial(obj.serialPort,...
'BaudRate',19200,...
'Parity','None',...
'StopBits',2,...
'FlowControl','None',...
'BytesAvailableFcn',{@rfcPerseusRead,obj},...
'BytesAvailableFcnMode','byte',...
'BytesAvailableFcnCount',1,...
'TimeOut',3,...
'Name',['SDR-Serial-',obj.serialPort],...
'Tag','perseusSerialObj') ;
Right now I accumulate the message response byte-by-byte:
function rfcPerseusRead(scr,~,obj)
ba = get(obj.serialObj,'BytesAvailable') ;
try
while ba > 0
dataDecimal = fread(obj.serialObj,1,'uint8') ;
obj.dataMsg = [obj.dataMsg,dec2hex(dataDecimal,2)] ;
ba = get(obj.serialObj,'BytesAvailable') ;
end
catch
try
while ba > 0
dataDecimal = fread(obj.serialObj,1,'uint8') ;
obj.dataMsg = [obj.dataMsg,dec2hex(dataDecimal,2)] ;
ba = get(obj.serialObj,'BytesAvailable') ;
end
catch
'disp('Read Error') ;
end
end
end
1 Kommentar
cr
am 5 Okt. 2013
Matlab allows only 0-127 for terminator character. Is the number of output bytes 6 per communication? If that is the case, increment your 'BytesAvailableFcnCount' to a multiple of 6. In the callback function extract the 3,4,5 bytes of interest.
Antworten (0)
Siehe auch
Kategorien
Mehr zu Instrument Control Toolbox finden Sie in Help Center und File Exchange
Produkte
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!