Hello,
I have a Simbiology PK model and the unit of all species (drug) is in microgram/milliliter. However, I would like to include a new reaction considering the drug and receptor binding behavior. The equation for this reaction is reversible as below.
Drug + Receptor <-> Complex: k_on*Drug*Receptor - k_off*Ccomplex
However, the unit of the k_on is 1/Molarity/Second and the unit of the k_off is 1/second and the unit for the Drug, Receptor and Complex should be in molarity. Is there any way I could keep my species unit still in microgram/milliliter but only have their unit become in molarity when they participate in this reaction? or is there any trick I could apply to achieve this thought?
Thank you very much.
Jesse

Akzeptierte Antwort

Arthur Goldsipe
Arthur Goldsipe am 2 Aug. 2021
I would recommend against mixing mass-based units and mole-based units for species participating in the same reaction. In such cases, it would be unclear which of these units would apply to the reaction rate. I personally would probably use molarity for all the species. If you also want to know the drug concentration in microgram/milliter, you can calculate that separately as a different output from your simulations. One option introduced in R2020a is to add an "observable" to your model for this. If you need a solution that also works in older versions of SimBiology, you could do something similar with a repeated assignment rule.
-Arthur

Weitere Antworten (0)

Communitys

Weitere Antworten in  SimBiology Community

Kategorien

Mehr zu Extend Modeling Environment finden Sie in Help Center und File Exchange

Produkte


Version

R2021a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by