struct memeber can not be Simulink.Parameter?
13 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
dayu lai
am 29 Jul. 2021
Beantwortet: Shivam Malviya
am 13 Sep. 2024
hi,
I am using HDL Coder to generate RTL code from simulink.
While I want some signal internal a simulink to be tunable, which names 'bp' for example. So I wrote following code:
bp = Simulink.Parameter;
bp.Value = [0;0;0];
bp.CoderInfo.StorageClass = 'ExportedGlobal';
Then the bp signal will appeared as a input port in RTL.
However, if I wrote like this:
reg.bp = Simulink.Parameter;
reg.bp.Value = [0;0;0];
reg.bp.CoderInfo.StorageClass = 'ExportedGlobal';
While generate RTL, it comes out error:
Invalid setting in '<some_block>' for parameter 'Value'.
error using slhdlcoder.SimulinkConnection/initModel
Expression 'reg.bp' for block '<some_block>' returns a Simulink.Parameter object that has property values that need to be evaluated. This object should be instantiated in a workspace and referenced by name in Simulink
So it seems struct member can not be simulink parameter?
1 Kommentar
Parker
am 11 Sep. 2024
I hope the Mathworks team will revisit this question and give an explanation for why this is not allowed. I have run into the same thing, where our team would like to store our parameters in a structure and use them in constant and gain blocks in our model, but Mathworks appears to have disallowed this starting with MATLAB r14sp3, per this older question
Akzeptierte Antwort
Shivam Malviya
am 13 Sep. 2024
Hi,
It appears that during the RTL code generation for the attached model, you are encountering the mentioned error due to the use of a struct variable with a field that is a Simulink.Parameter. In your use case, struct variables are necessary to bundle all the global tunable parameters together.
The current initialization of the `reg` variable is causing Simulink model compilation failure, which leads to an error during RTL code generation. To resolve this issue, please follow these steps:
- Instead of setting the field as a Simulink.Parameter, set the top-level struct as a Simulink.Parameter.
- Ensure that the appropriate bus object is set for the struct object of type Simulink.Parameter.
Below is the updated demo_param.m script, which correctly initializes the reg variable:
% Initialize the required value
thr_val = [5;6;7];
reg_val = struct('thr', thr_val);
% Create appropriate bus object
Simulink.Bus.createObject(reg_val);
regType = slBus1;
clear slBus1
% Create the Simulink.Parameter object
reg = Simulink.Parameter(reg_val);
reg.DataType = 'Bus: regType';
reg.CoderInfo.StorageClass = 'ExportedGlobal';
% Set required variables
DT_cnt = fixdt(0,8,0);
ts = 0.1;
However, input ports won't get generated in the RTL code for this scenario involving struct as a Simulink.Parameter.
For more details, please refer to the following documentation pages:
- https://www.mathworks.com/help/simulink/ug/using-structure-parameters.html#bu1k073
- https://www.mathworks.com/help/simulink/slref/simulink.bus.createobject.html
Best Regards,
Shivam Malviya
0 Kommentare
Weitere Antworten (2)
Kiran Kintali
am 1 Aug. 2021
Can you share a sample model?
2 Kommentare
Parker
am 11 Sep. 2024
I would love for an explanation from Mathworks about why this method of storing parameters is not allowed by Simulink
Kiran Kintali
am 11 Sep. 2024
These pages contain good info on allowed ExportedGlobal usage in HDL Coder
0 Kommentare
Siehe auch
Kategorien
Mehr zu Speed Optimization finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!