custom ROS service bus assignment
4 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Nathaniel Goldfarb
am 25 Mai 2021
Kommentiert: Nathaniel Goldfarb
am 26 Mai 2021
Hello,
I am trying to call a ROS service using a custom service message in simulink. I have successfuly followed the instruction here: https://www.mathworks.com/help/ros/ug/create-custom-messages-from-ros-package.html to load the custom message into Matlab.
I need to do some string assignment in the message, I have been following the JointState publisher example to assaign the string array.
The problem I am running into is I cannot figure out what the Bus type should be sent too.
My message type is rbdl_server/RBDLInverseDynamicsRequest
So I assigned the bus type: SL_Bus_sliding_controller_rbdl_server_RBDLInverseDynamicsRequest
Which is causing the follow error:
=== Update Diagram (Elapsed: 1 sec) ===
Error:Expression 'SL_Bus_sliding_controller_rbdl_server_RBDLInverseDynamicsRequest' for type of data 'msg' did not evaluate to a valid type.
Caused by:
Invalid setting in 'sliding mode controller/MATLAB Function - String Array Assign1' for parameter 'Datatype'
Error evaluating MATLAB Function parameter data 'Datatype' in its parent workspace.
Unrecognized function or variable 'SL_Bus_sliding_controller_rbdl_server_RBDLInverseDynamicsReques'.
Variable 'SL_Bus_sliding_controller_rbdl_server_RBDLInverseDynamicsReques' does not exist.
what am I doing wrong? It seems like the message name is being truncated (missing the "t" at the end of the name) but I am not sure why that is happening or to fix that.
2 Kommentare
Abhijeet Gadkari
am 26 Mai 2021
Bearbeitet: Abhijeet Gadkari
am 26 Mai 2021
Hello Nathaniel,
Could you please confirm the value of “DataType” parameter you entered in the MATLAB function block editor - if it matches the name of the bus? Also, could you please share some more information for further debugging:
- Abhijeet
Akzeptierte Antwort
Abhijeet Gadkari
am 26 Mai 2021
Bearbeitet: Abhijeet Gadkari
am 26 Mai 2021
Hello Nathaniel,
Thanks for the information, that was helpful. From the snap-shot of your model, it seems you are using R2019b (please verify using "ver" command in MATLAB).
Verify the names of the buses in your base-workspace.
whos SL_Bus_sliding_controller*
% Output should look as follows:
% Name Size Bytes Class Attributes
%
% SL_Bus_sliding_controller_RBDLInverseDynamicsReques_3qoi39 1x1 1890 Simulink.Bus
% SL_Bus_sliding_controller_geometry_msgs_Point 1x1 220 Simulink.Bus
% SL_Bus_sliding_controller_std_srvs_EmptyRequest 1x1 148 Simulink.Bus
% SL_Bus_sliding_controller_std_srvs_EmptyResponse 1x1 150 Simulink.Bus
The service request bus name (if it followed the convention of model name appended by request message name) would have been longer than 63 character limit.
length('SL_Bus_sliding_controller_rbdl_server_RBDLInverseDynamicsRequest')
So, generated bus name is truncated to meet the 63 character limit and unique hash string is appended to it.
It's recommended to use the data-type drop-down in MATLAB function editor to select the correct Simulink bus data-type.
-Abhijeet
Weitere Antworten (0)