Error: "Not enough input arguments"

8 Ansichten (letzte 30 Tage)
Eduardo Braga
Eduardo Braga am 6 Mär. 2021
Kommentiert: Eduardo Braga am 6 Mär. 2021
Hi. I'm new to matlab and I'm trying to optimize a distillation column with the NSGA II algorithm. However, I am having the following error: "Not enough input arguments". Can someone help me?
function [Obj, Cons] = Fun_Objective(X)
global Aspen
Stages = X(1) + 2;
Pressure = X(2);
Feed_Stage = round((Stages-4)*X(3) + 2);
Aspen.Tree.FindNode("\Data\Blocks\B2\Input\NSTAGE").Value = Stages;
Aspen.Tree.FindNode("\Data\Blocks\B2\Subobjects\Column Internals\INT-1\Input\CA_STAGE2\INT-1\CS-1").Value = Stages - 1;
Aspen.Tree.FindNode("\Data\Blocks\B2\Input\PRES1").Value = Pressure;
Aspen.Tree.FindNode("\Data\Blocks\B2\Input\FEED_STAGE\S50").Value = Feed_Stage;
Aspen.Reinit; % Reinit simulation
Aspen.Engine.Run2(1); %Run the simulation. (1) ---> Matlab isnt busy; (0) Matlab is Busy;
time = 1;
Error = 0;
while Aspen.Engine.IsRunning == 1 % 1 --> If Aspen is running; 0 ---> If Aspen stop.
pause(0.5);
time = time+1;
if time==600 % Control of simulation time.
Aspen.Engine.Stop;
Error = 1;
end
end
Conv = Aspen.Tree.FindNode("\Data\Results Summary\Run-Status\Output\PER_ERROR").Value; %Convergence Assessment
if Error == 0 && Conv == 0
Pur = Aspen.Tree.FindNode("\Data\Streams\S4\Output\MASSFLOW\MIXED\ACROL-01").Value/Aspen.Tree.FindNode("\Data\Streams\S4\Output\MASSFLMX\MIXED").Value;
Purity = 0.95 - Pur; %This means: Pur > 0.95 mol frac.
%Recovery > 0.98
Recovery = 0.98 - (Aspen.Tree.FindNode("\Data\Streams\S4\Output\MASSFLOW\MIXED\ACROL-01").Value/Aspen.Tree.FindNode("\Data\Streams\S50\Output\MASSFLOW\MIXED\ACROL-01").Value);
%Constraints Vector
c(1,1) = Purity;
c(1,2) = Recovery;
Cons = (c>0).*c; %Only accept unsatisfied constrainst: c > 0
CAPEX = AcrilonitrilaCAPEX()/10; %Fixed Distillation Cost
OPEX = AcrilonitrilaOPEX(); %Operating Distillation Cost
Obj = [CAPEX, OPEX]; %Objectives Function. CAPEX vs OPEX
else
Obj = [2e7, 2e7];
Cons = [1, 1];
end
end
  2 Kommentare
Walter Roberson
Walter Roberson am 6 Mär. 2021
Where is the error message being generated? What is the code you are using to run this code?

Melden Sie sich an, um zu kommentieren.

Akzeptierte Antwort

Walter Roberson
Walter Roberson am 6 Mär. 2021
You cannot run the objective function directly: you need to run a function such as the supplied Opt* function which sets up the conditions for everything to be called.

Weitere Antworten (0)

Kategorien

Mehr zu Distillation Design finden Sie in Help Center und File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by