FIR filter has output of same length as its input?

6 Ansichten (letzte 30 Tage)
Nader Rihan
Nader Rihan am 27 Dez. 2020
Kommentiert: Nader Rihan am 27 Dez. 2020
If the input signal has length L samples, impulse repsonse has length M samples, entering these L samples to FIR filter using conv function, will get L+M-1 output samples, while entering these L samples to FIR fitler, the output has L samples only instead of L+M-1 samples . Also, I'd like to know which L samples does FIR filter choose from L+M-1 samples (total samples) to be its output ?.

Akzeptierte Antwort

Bruno Luong
Bruno Luong am 27 Dez. 2020
Bearbeitet: Bruno Luong am 27 Dez. 2020
There is the the difference equation in the "Rational Transfer Function" part of the doc. x(i) with i<=0 are supposed to be 0.
and you can figure out easily just by experiment
>> x=rand(1,10)
x =
0.1576 0.9706 0.9572 0.4854 0.8003 0.1419 0.4218 0.9157 0.7922 0.9595
>> b=rand(1,3)
b =
0.9340 0.6787 0.7577
>> conv(x,b) % <= 'full' option
ans =
0.1472 1.0135 1.6722 1.8385 1.8022 1.0435 1.0966 1.2491 1.6810 2.1277 1.2515 0.7270
>> filter(b,1,x)
ans =
0.1472 1.0135 1.6722 1.8385 1.8022 1.0435 1.0966 1.2491 1.6810 2.1277

Weitere Antworten (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!