Issues with building a fan using a BLDC and a controlled volumetric flowrate source
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
Renee Jerome
am 22 Dez. 2020
Kommentiert: Adedoyin Abatti
am 14 Mai 2021
I'm trying to design a fan where it only blows air in one direction and the issue is connecting the R output of the BLDC to the controlled volumetric flowrate source.
My project entails building a Hot air blower simulation model which will be customisable.
1 Kommentar
Akzeptierte Antwort
Juan Sagarduy
am 22 Dez. 2020
Hello Renée
You need to connect the shaft of the BLDC motor (electric to mechanic) to a component converting mechanic to pneumatic (gas) energy.
See the link below to the fan element (Simscape Fluids) https://se.mathworks.com/help/physmod/hydro/ref/fang.html
There is also a component in Simscape. https://se.mathworks.com/help/physmod/simscape/ref/rotationalmechanicalconverterg.html
Hope this helped Regards / Juan