Varying results for the same model
2 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
We are modelling a combined cycle pwer plant. When we ran GT seperatly we got the desired result for exhaust temperature, but when we connected the GT to HRSG and ST we got a different result.. My question is, how can GT results change if it is at the beginning of the model and nothing goes back to it ?
0 Kommentare
Antworten (1)
Paul
am 27 Nov. 2020
If you are using a variable step solver, including HRSG and ST can cause the outputs of GT1 and GT2 to change if HRSG and/or ST cause the solver to adjust its step size differently as compared to when they are not included. Should be a small difference, unless in the first case the solver was taking very large steps compared to the second.
0 Kommentare
Communitys
Weitere Antworten in Power Electronics Control
Siehe auch
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!