Eject entity from server when failure occurs
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
Sander van den Heuvel
am 24 Nov. 2020
Bearbeitet: Sander van den Heuvel
am 25 Nov. 2020
Hi there,
On page 2-28 of the simevents documentation there is noted: "If you want to eject the current entity from the server upon a failure occurence, then you can use the preemption feature of the server to replace the current entity with a high-priority placeholder". This is a nice note, but I am unsure how to model such a situation when a failure is modeled in the same way as in the example on page 2-28 (via an entity gate)? How can the failure gate and the entity server communicate when a failure occurs and preempt the order that is processed at that moment from the server, give it a high priority and a residual processing time and send it back to the queue?
In the attachments you can find an example with explanation of what I am trying to achieve.
Thank you very much
0 Kommentare
Akzeptierte Antwort
Abdolkarim Mohammadi
am 24 Nov. 2020
Generally speaking, failures are preempted entities that does not consume resources. They are generated from another entity generator of the same type of the main entities, but are generated in another route, so that they do not acquire resources. The routes of normal entities and failures are then combined with each other via Entity Input Switch block.
1 Kommentar