Error: "Each physical network must be connected to exactly one Solver Configuration block. There is no Solver Configuration block connected to Physical Network with the following blocks..."
148 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
I would like to Implement the following (see image on the left) Pulse Width Modulation (PWM) circuit on Simulink (see image on the right). However, i keep getting the following error:
"Each physical network must be connected to exactly one Solver Configuration block. There is no Solver Configuration block connected to Physical Network with the following blocks..."
Could someone help me out? Thanks!
0 Kommentare
Antworten (2)
Pemendra Kumar Pardhi
am 4 Nov. 2020
Dear,
You have to recuired Solver Configuration block at grounding point as shown in attached file
the Solver Configuration Block can be obtained from
Simulink Library> simscape>foundation library> utilies
3 Kommentare
Joel Van Sickel
am 4 Nov. 2020
Hello,
the solver configuration block is a simscape block under utilities that you can connect to any part of your simscape network. It associates local solver settings for that simscape network since simscape uses more complex solver's than simulink does. You should be able to start with the default settings.
Regards,
Joel
0 Kommentare
Communitys
Weitere Antworten in Power Electronics Control
Siehe auch
Kategorien
Mehr zu Simscape Electrical finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!