Orientation of “Three-Phase V-I Measurement” block and direction of power flow
4 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Miroslav Blagojevic
am 26 Sep. 2020
Kommentiert: Miroslav Blagojevic
am 1 Okt. 2020
I use “Three-Phase V-I Measurement” block to measure Vabc and Iabc, and then use “Power (3ph, Phasor)” block to calculate P and Q. Could someone please confirm that positive P or Q means that power flows from capital A B C letters on “Three-Phase V-I Measurement” block towards small a b c on the same block. Or is there a completely different logic?
There is a figure on “Power (3ph, Phasor)” block’s help page, but its meaning is not clear to me.
0 Kommentare
Akzeptierte Antwort
Rhea Chandy
am 1 Okt. 2020
Hi!
I understand that you want to know whether positive P and Q implies that power flows from the capital notation ABC letters on the block through the letters abc notation.
Indeed, yes, that is the case regarding the Three-Phase V-I Measurement block. An example,
power_PhasorPowerMeasurements
shows the use of both the Power (3ph, Phasor) block and the three-Phase V-I Measurement block in simscape. This may help you gain an understand of the direction of power flow. The example is listed in the documentation for Power (3ph, Phasor) block.
Weitere Antworten (0)
Siehe auch
Kategorien
Mehr zu Simulation and Analysis finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!