Multiple NI Chassis Data Acquisition in multiple sessions
Ältere Kommentare anzeigen
I am trying to acquire data from 3 NI data acquisition chassis simultaneously (2 cDAQ 9191 and 1 cDAQ 9184). When I try to use one single session for all three data acquisition objects it throws an NI error 200414 "Requested sample clock is invalid." I can acquire data using three different daq sessions but the data shows a significant phase lag of about 0.5-1.0 sec which is unacceptable. I am plotting event.TimeStamps vs. event.Data. After speaking with tech support, the commands s.StartBackground should start the daq devices almost simultaneously and they think event.Timestamps are created by Matlab which is why it shows a lag. Are event.TimeStamps created by the chassis or matlab itself? Is there a better way to synchronize the data? The chassis do not have a terminal to add an external trigger or clock.
handles.ai=daq.createSession('ni');
handles.ai1=daq.createSession('ni');
handles.ai2=daq.createSession('ni');
handles.sensitivities = xlsread('SensorInfo','C2:C25');
for i=4
handles.chan = handles.ai.addAnalogInputChannel('ModalDAQMod1',i-1,'Accelerometer');
handles.chan.InputType='PseudoDifferential';
handles.chan.Coupling='AC';
handles.chan.Sensitivity=handles.sensitivities(i);
handles.chan = handles.ai1.addAnalogInputChannel('ModalDAQ2Mod1',i-1,'Accelerometer');
handles.chan.InputType='PseudoDifferential';
handles.chan.Coupling='AC';
handles.chan.Sensitivity=handles.sensitivities(i);
handles.chan = handles.ai2.addAnalogInputChannel('ModalDAQ3Mod1',i-1,'Accelerometer');
handles.chan.InputType='PseudoDifferential';
handles.chan.Coupling='AC';
handles.chan.Sensitivity=handles.sensitivities(i);
handles.chan = handles.ai2.addAnalogInputChannel('ModalDAQ3Mod2',i-1,'Accelerometer');
handles.chan.InputType='PseudoDifferential';
handles.chan.Coupling='AC';
handles.chan.Sensitivity=handles.sensitivities(i);
end
handles.ai.Rate= round(floor(2048));
handles.ai.DurationInSeconds=80;
handles.ai.NotifyWhenDataAvailableExceeds=2048*4;
handles.ai.IsContinuous=false;
handles.ai1.Rate= 2048;
handles.ai1.DurationInSeconds=80;
handles.ai1.NotifyWhenDataAvailableExceeds=2048*4;
handles.ai1.IsContinuous=false;
handles.ai2.Rate= 2048;
handles.ai2.DurationInSeconds=80;
handles.ai2.NotifyWhenDataAvailableExceeds=2048*4;
handles.ai2.IsContinuous=false;
handles.lh = handles.ai.addlistener('DataAvailable', @(src,event) temp_1(src,event,handles)); % creates a new listener.
handles.lh1 = handles.ai1.addlistener('DataAvailable', @(src,event) temp_2(src,event,handles)); % creates a new listener.
handles.lh2 = handles.ai2.addlistener('DataAvailable', @(src,event) temp_3(src,event,handles)); % creates a new listener.
handles.ai.prepare
handles.ai1.prepare
handles.ai2.prepare
handles.ai.startBackground();
handles.ai1.startBackground();
handles.ai2.startBackground();
2 Kommentare
Austin Bond
am 24 Apr. 2013
I second this question!
MathWorks support would be nice here!!!
Kelvin
am 11 Nov. 2014
How did you start multiple sessions simultaneously? I cannot start a second session once the first one is running.
Antworten (0)
Kategorien
Mehr zu National Instruments Frame Grabbers finden Sie in Hilfe-Center und File Exchange
Produkte
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!