How to set parameters of Recursive Polynomial Model Estimator in Simulink
3 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Ziyang Zhang
am 8 Jul. 2020
Kommentiert: Ziyang Zhang
am 10 Jul. 2020
Hello! everyone,
I have a question when using the Recursive Polynomial Model Estimator. I am trying to achieve the online estimation of a two-input two-output system. So my settings are na: [2,2;2,2], nb: [1,1;1,1]; nk: [1,1;1,1]. But there is an error that shows the number of parameters in na must be a scalar. Why is there such an error? How to fix it?
Thanks.
0 Kommentare
Akzeptierte Antwort
Rajiv Singh
am 8 Jul. 2020
The Recursive Polynomial Model Estimator supports single output estimations only.
5 Kommentare
Rajiv Singh
am 9 Jul. 2020
The recursive estimation features are limited right now and we plan to remove I/O size limitations in future. Right now, one possibility is to use a different estimator for each output. If you have multiple inputs too, you can only use the ARX recursive estimator.