Hello, PID Turner can import Plant tranfer functions for the PID design. Is there a way to set also the transfer function of the feedback loop (e.g. Sensor's frequency response) ? Thanks ahead for a reply.

Antworten (1)

Arkadiy Turevskiy
Arkadiy Turevskiy am 7 Okt. 2020

0 Stimmen

No, there is no way to specify transfer function of other components. For PID Tuner, "Plant" is all system dynamics except for the controller.
Hope this helps.
Arkadiy

1 Kommentar

Tony
Tony am 21 Sep. 2023
I think, it is fine when the sensor tranfer function (G_sensor) is included into Plant: Plant_new = Plant * G_sensor. Because the Openloop: G0 = G_controller * Plant * G_sensor
Correct me please, if Iam wrong.
Thanks
Tony

Melden Sie sich an, um zu kommentieren.