1-d heat transfer equation
3 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
chang hoon oh
am 12 Jun. 2020
Beantwortet: Walter Roberson
am 12 Jun. 2020
now i am wirte the heat equation code. it tisn't work ,,
L=10cm, dx=1cm n=10 T(11,200)
the initial condition is T(*,1)= 293K
the boundary condition is T(1,*)=373k , T(11,*)=T(10,*)
and this is my code
clear
clc
L=10;
n=11;
dx=L/n;
dt=0.005;
t=1;
nt=200;
alpha=0.001;
beta=alpha*dt*(1/(dx)^2);
T0=293;
T1=373;
for j=1:nt
for i=2:n-1
T1(i)=((1-2*beta)*T0(i)+beta*T0(i-1)+beta*T0(i+1));
end
end
plot(T1)
1 Kommentar
Akzeptierte Antwort
Walter Roberson
am 12 Jun. 2020
T0=293;
That is a scalar.
for i=2:n-1
i starts at 2
T1(i)=((1-2*beta)*T0(i)+beta*T0(i-1)+beta*T0(i+1));
You use T0(i) and T0(i+1) . On the first iteration that would be trying to access T0(2) and T0(2+1) . But T0 is a scalar.
for j=1:nt
Your for i loop does not use j at all, and has no feedback -- the calculation of T1(i) has no reliance on T1(i) calculated from an earlier for j value. Therefore in your code, your for j is a waste of time: every j iteration is going to produce the same T1 vector.
0 Kommentare
Weitere Antworten (0)
Siehe auch
Kategorien
Mehr zu Thermal Analysis finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!