Zynq SDR Capture Length question!
2 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
jarul
am 5 Jun. 2020
Kommentiert: jarul
am 19 Jun. 2020
While using Zynq SDR, the capture length can not exceed '16777216'.
I want to capture length longer than the prescribed. I get the following error.
Error using comm.libiio.AD9361.rx/capture
Requested capture length (23592960 Samples) exceeds maximum value for this number of channels
(16777216 Samples). Use 'EnableOversizeCapture' to risk compromising data contiguity in return for a
larger capture length.
How to use 'EnableOversizeCapture in order to capture longer length than the one prescribed.
Thanks.
0 Kommentare
Akzeptierte Antwort
Jyotsna Talluri
am 8 Jun. 2020
You can just enable the property'EnableOversizeCapture' by setting it to true.In addition to the other arguments of capture function,specify it as a name -value pair.
capture(rxsdr,'EnableOversizeCapture',true);
Refer to the below documentation link for more information
Weitere Antworten (1)
jarul
am 9 Jun. 2020
2 Kommentare
Neil MacEwen
am 16 Jun. 2020
Hi Jarul,
Both transmitRepeat and capture methods use on-board storage, which is size-limited. When you select "EnableOversizeCapture" you are choosing to stream data to the host, instead of capturing it on on-board storage first - this is why you are no longer guaranteed contiguity, as you may lose samples over the Ethernet link.
Likewise, on the transmit side, the only way you can send a frame of a size larger than the 16M limit is by attempting to stream in real-time from the host, instead of using transmitRepeat. Again, you will not be guaranteed contiguity, and are likely to see performance issues (dropped samples).
Thanks,
Neil
Siehe auch
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!