Simulink get_param and RuntimeObject

22 Ansichten (letzte 30 Tage)
Alexandru
Alexandru am 6 Nov. 2012
Hello!
Is there a way to write this command: rto_add = get_param('TestMdl2/Add','RuntimeObject'); in one of the "Model callbacks" and to work while running the simulation?
I read that is possible to get the result if I use the PostLoadFcn function. The article said: "In a PostLoadFcn callback routine, however, get_param returns the model's parameter values because the model is loaded."
But it's not working...
What I want to do is to get my result and to display it on a GUI, but in real time while running the simulation.
Thanks!

Akzeptierte Antwort

Ryan G
Ryan G am 6 Nov. 2012
  1 Kommentar
Kaustubha Govind
Kaustubha Govind am 6 Nov. 2012
Ryan: I wonder if the second link is supposed to point to this topic: http://www.mathworks.com/help/simulink/ug/accessing-block-data-during-simulation.html
Alexandru: In general, get_param should indeed work in or after the PostLoadFcn to query parameter settings. However, the RuntimeObject property is only accessible during simulation. Of all the model callback functions, the only ones that may be called during simulation are PauseFcn and ContinueFcn - the right way to use the RuntimeObject is using event listeners as Ryan suggested.

Melden Sie sich an, um zu kommentieren.