Error loading Simulink with Simscape blocks
Ältere Kommentare anzeigen
I have a problem opening Simulink Models that contain Simscape blocks. When I open the model the Matlab Command Window displays:
"Warning: Physical modeling domain definition file input.m not found. You will not be able simulate this model. Please close your model, then add the domain definition file to the MATLAB path and re-open your model.
Warning: Physical modeling domain definition file output.m not found. You will not be able simulate this model. Please close your model, then add the domain definition file to the MATLAB path and re-open your model."
The Simulink Diagnostic Viewer displays for every single Simscape block I used: "['Modell_Kreiselpumpe_Motor_Kreislauf_03032020/Ammonium-Water']: Parameter check for block 'Modell_Kreiselpumpe_Motor_Kreislauf_03032020/Ammonium-Water' failed.
Caused by:
- Too many output arguments.
Component:Simulink | Category:Model error"
I already tried to add the input.m resp. output.m file but I could not find it.
How can I solve this problem?
Akzeptierte Antwort
Weitere Antworten (0)
Kategorien
Mehr zu Nonlinear Operators finden Sie in Hilfe-Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!