Is there a way to count all connections between blocks in a Simulink model including masked subsystems?
I am currently using the following code which seems to only get me the connections within non-masked subsystems.
lineHandles = find_system(modelName,'FindAll','on','type','line');
lineDim = size(lineHandles);
lines = lineDim(1,1);
count = 0;
for k = 1:lines
dst = get_param(lineHandles(k),'DstBlockHandle');
if any(dst==-1) || ismember(-1, dst)
continue
end
dst_names = get_param(dst,'Name');
if ~iscell(dst_names)
count = count + 1;
end
end
Any help or pointers would be greatly appreciated!

Antworten (1)

Guru Mohanty
Guru Mohanty am 15 Mai 2020

0 Stimmen

You can count the number of connections under a mask with the help of the following block parameter setting.
lineHandles = find_system(modelName,'LookUnderMasks', 'on','FindAll','on','type','line');