PID BLOCK IN SIMULINK

13 Ansichten (letzte 30 Tage)
Uzair Akhtar
Uzair Akhtar am 13 Apr. 2020
Kommentiert: Ameer Hamza am 14 Apr. 2020
I have worked out that my PID controller is
Gc = 4.2(1 + 1/1.57s + 0.39s)
I want to put this into a block on simulink but the PID controller block in simulink is in a weird form. Does anyone know how to get around this. Thanks.

Akzeptierte Antwort

Ameer Hamza
Ameer Hamza am 13 Apr. 2020
In the Simulink PID block, In the form field, change the form from parallel to ideal and set the value of filter coefficient N to be quite high (say 200). Then parameters P, I, and D can be used from your current transfer function.
  2 Kommentare
Uzair Akhtar
Uzair Akhtar am 13 Apr. 2020
Thank you. Do you know what impact the filter coefficient N has to the system.
Ameer Hamza
Ameer Hamza am 14 Apr. 2020
PID block uses a low-pass filter for D term. The value of N controls the stop-band of the low-pass filter. Higher the value of N, higher is the stop-band frequency. For the low-value of N, the PID block will smooth the derivative of your system. If you have a high value of N, the filter will have no significant effect.