When is the 'ModelRefe​renceVersi​onMismatch​Message' Simulink model parameter editable?

1 Ansicht (letzte 30 Tage)
When I open a model's test harness, I receive the following error:
I would like to disable the "ModelReferenceVersionMismatchMessage" parameter, but when I go to the configuration parameters, it's greyed-out and I can't modify it. When I try to edit it from the command line, I also receive errors:
The documentation page for this parameter doesn't give any hints as to when it is possible to actually edit it. How can I edit it?

Akzeptierte Antwort

Fangjun Jiang
Fangjun Jiang am 9 Apr. 2020
Try this
model='sldemo_mdlref_basic';
open_system(model);
get_param(model,'ModelReferenceVersionMismatchMessage')
set_param(model,'ModelReferenceVersionMismatchMessage','warning')
set_param(model,'ModelReferenceVersionMismatchMessage','none')
  3 Kommentare
Fangjun Jiang
Fangjun Jiang am 20 Apr. 2020
Yes. In the .tlc file, you can disable certain configuration parameters. Open the .tlc file to see if you can find the source.
Monika Jaskolka
Monika Jaskolka am 20 Apr. 2020
Bearbeitet: Monika Jaskolka am 20 Apr. 2020
Thank you. You're right. I can enable the parameter by modifying the custom .tlc file like this:
slConfigUISetEnabled(hDlg, hSrc, 'ModelReferenceVersionMismatchMessage', 'true');

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (0)

Kategorien

Mehr zu Simulink Environment Customization finden Sie in Help Center und File Exchange

Produkte


Version

R2016b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by