When is the 'ModelReferenceVersionMismatchMessage' Simulink model parameter editable?
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
Monika Jaskolka
am 7 Apr. 2020
Bearbeitet: Monika Jaskolka
am 20 Apr. 2020
I would like to disable the "ModelReferenceVersionMismatchMessage" parameter, but when I go to the configuration parameters, it's greyed-out and I can't modify it. When I try to edit it from the command line, I also receive errors:
The documentation page for this parameter doesn't give any hints as to when it is possible to actually edit it. How can I edit it?
0 Kommentare
Akzeptierte Antwort
Fangjun Jiang
am 9 Apr. 2020
Try this
model='sldemo_mdlref_basic';
open_system(model);
get_param(model,'ModelReferenceVersionMismatchMessage')
set_param(model,'ModelReferenceVersionMismatchMessage','warning')
set_param(model,'ModelReferenceVersionMismatchMessage','none')
3 Kommentare
Fangjun Jiang
am 20 Apr. 2020
Yes. In the .tlc file, you can disable certain configuration parameters. Open the .tlc file to see if you can find the source.
Weitere Antworten (0)