Filter löschen
Filter löschen

MPC cannot be designed in app

26 Ansichten (letzte 30 Tage)
Dhruv Thakkar
Dhruv Thakkar am 17 Mär. 2020
Kommentiert: JGP am 20 Mär. 2024
I have a Carsim S-functon as the plant model for a MPC. But I get an error saying "Plant model cannot be a pure direct feed-through system without additional dynamics". Why does it keep saying that?
  4 Kommentare
Kumar Prabhakar
Kumar Prabhakar am 29 Mai 2021
SIR HAVE YOU SOLVED THE SAME PROBLEM
TELL ME HOW
zhanglong zhang
zhanglong zhang am 11 Jun. 2021
hello, i also have the problem,may you tell me how can i solve it? thank you.

Melden Sie sich an, um zu kommentieren.

Antworten (3)

Junhao Jiang
Junhao Jiang am 22 Apr. 2020
The compatibility between CarSim and Simulink is not high,if you have the state space,you should use it,or you only choose the s-function to make it.
  3 Kommentare
Pacifique Turabimana
Pacifique Turabimana am 27 Dez. 2021
How can I add CarSim S-Function in Simulink Library?
I tried to link CarSim with Simulink but nothing to do after because I can't find CarSim in Simulink library, I tried even online MATLAB but I can't be ab;e to continue working on my research. Please guide me to solve it.
Walter Roberson
Walter Roberson am 27 Dez. 2021
Unfortunately carsim.com does not appear to post their installation documentation online :(

Melden Sie sich an, um zu kommentieren.


Walter Roberson
Walter Roberson am 11 Jun. 2021
According to https://www.mathworks.com/matlabcentral/answers/473358-mpc-controller-direct-feedthrough-from-manipulated-variables-to-any-output-in-plant-is-not-allowed#comment_961921 you currently have an output that is being calcuated from an input signal with no modeled delay, but MPC does not permit that. You need to configure your model to take some time between input and output for all signals.
You can use delay blocks, or you can use a transfer function.
  4 Kommentare
MUHAMMAD
MUHAMMAD am 8 Dez. 2023
Solution:
I had same problem and It is solve by adding time delay.
You can add time delay in between MV and plant. I did using matlab command like like
plant = tf([num],[den],'OutputDelay',1.5 )
I hope this answer helped you.
Example
%%Transfer Function By System identification
num = [-1.324 6.6e05 -6.914e09 5.128e13 -1.054e19]
den = [1 1.99e04 1.371e09 1.145e13 4.037e17]
plant = tf([num],[den],'OutputDelay',1.5 )
JGP
JGP am 20 Mär. 2024
can you help me? Even if I use the delay or LTI system, the error continues.
How do I insert the Matlab code you mentioned into Simulink?

Melden Sie sich an, um zu kommentieren.


MUHAMMAD
MUHAMMAD am 8 Dez. 2023
Solution:
I had same problem and It is solve by adding time delay.
You can add time delay in between MV and plant. I did using matlab command like like
plant = tf([num],[den],'OutputDelay',1.5 )
I hope this answer helped you.
Example
%%Transfer Function By System identification
num = [-1.324 6.6e05 -6.914e09 5.128e13 -1.054e19]
den = [1 1.99e04 1.371e09 1.145e13 4.037e17]
plant = tf([num],[den],'OutputDelay',1.5 )

Kategorien

Mehr zu Linear Plant Specification finden Sie in Help Center und File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by