MPC cannot be designed in app
Ältere Kommentare anzeigen
I have a Carsim S-functon as the plant model for a MPC. But I get an error saying "Plant model cannot be a pure direct feed-through system without additional dynamics". Why does it keep saying that?
4 Kommentare
Pengshan Dai
am 17 Apr. 2020
I have the same problem, do you have a solution already?
Dhruv Thakkar
am 26 Apr. 2020
Kumar Prabhakar
am 29 Mai 2021
SIR HAVE YOU SOLVED THE SAME PROBLEM
TELL ME HOW
zhanglong zhang
am 11 Jun. 2021
hello, i also have the problem,may you tell me how can i solve it? thank you.
Antworten (3)
Junhao Jiang
am 22 Apr. 2020
1 Stimme
The compatibility between CarSim and Simulink is not high,if you have the state space,you should use it,or you only choose the s-function to make it.
3 Kommentare
Dhruv Thakkar
am 26 Apr. 2020
Pacifique Turabimana
am 27 Dez. 2021
How can I add CarSim S-Function in Simulink Library?
I tried to link CarSim with Simulink but nothing to do after because I can't find CarSim in Simulink library, I tried even online MATLAB but I can't be ab;e to continue working on my research. Please guide me to solve it.
Walter Roberson
am 27 Dez. 2021
Unfortunately carsim.com does not appear to post their installation documentation online :(
Walter Roberson
am 11 Jun. 2021
0 Stimmen
According to https://www.mathworks.com/matlabcentral/answers/473358-mpc-controller-direct-feedthrough-from-manipulated-variables-to-any-output-in-plant-is-not-allowed#comment_961921 you currently have an output that is being calcuated from an input signal with no modeled delay, but MPC does not permit that. You need to configure your model to take some time between input and output for all signals.
You can use delay blocks, or you can use a transfer function.
4 Kommentare
zhanglong zhang
am 12 Jun. 2021
I added the delay module, but this is still the mistake. Please kindly guide me. Thank you very much.
as shown below:


MUHAMMAD
am 8 Dez. 2023
How did you solved this problem? I am facing same problem
MUHAMMAD
am 8 Dez. 2023
Solution:
I had same problem and It is solve by adding time delay.
You can add time delay in between MV and plant. I did using matlab command like like
plant = tf([num],[den],'OutputDelay',1.5 )
I hope this answer helped you.
Example
%%Transfer Function By System identification
num = [-1.324 6.6e05 -6.914e09 5.128e13 -1.054e19]
den = [1 1.99e04 1.371e09 1.145e13 4.037e17]
plant = tf([num],[den],'OutputDelay',1.5 )
JGP
am 20 Mär. 2024

can you help me? Even if I use the delay or LTI system, the error continues.
How do I insert the Matlab code you mentioned into Simulink?
MUHAMMAD
am 8 Dez. 2023
Solution:
I had same problem and It is solve by adding time delay.
You can add time delay in between MV and plant. I did using matlab command like like
plant = tf([num],[den],'OutputDelay',1.5 )
I hope this answer helped you.
Example
%%Transfer Function By System identification
num = [-1.324 6.6e05 -6.914e09 5.128e13 -1.054e19]
den = [1 1.99e04 1.371e09 1.145e13 4.037e17]
plant = tf([num],[den],'OutputDelay',1.5 )
Kategorien
Mehr zu Controller Creation finden Sie in Hilfe-Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!