Filter löschen
Filter löschen

Standalone PV array producing negative voltage.

10 Ansichten (letzte 30 Tage)
EngTat Chung
EngTat Chung am 11 Mär. 2020
Verschoben: Sabin am 4 Jan. 2023
I am trying to compare the power from my pv array and my battery to the load. I noticed my PV array power is negative and I am not sure why. The output power is also very low compared to my input from PV array and Battery. Please refer to the attached PDF file for the images.
Please I would like to seek assistance on this issue.

Antworten (1)

Jonathan LeSage
Jonathan LeSage am 13 Mär. 2020
Verschoben: Sabin am 4 Jan. 2023
I took a look at the schematic and I don't see anything immediately wrong. I would recommend commenting out the battery model to start and have the model run with only the PV array as the source. Once you confirm that this can provide the correct power load to the motor, work on adding back the battery.
The other thing that comes to mind is that the MPPT algorithm for solar might affect the DC bus voltage, which effects the converter for the battery system. You could change the solar inverter controller to hold a steady DC bus and then use the battery to charge/discharge. You could use something similar to the following example:
>> parallel_battery_SC_boost_converter
  1 Kommentar
EngTat Chung
EngTat Chung am 13 Mär. 2020
Verschoben: Sabin am 4 Jan. 2023
I will look into that, thank you very much!

Melden Sie sich an, um zu kommentieren.